Characteristics
Main range of product Harmony Kproduct or component type Complete cam switchcomponent name K115[Ith] conventional free air thermal current 115 Amounting location Frontfixing mode 4 holescam switch head type With front plate 88 x 88 mmtype of operator Black handlerotary handle padlocking Withoutpresentation of legend With metallic legend, 1 - 2 black markingcam switch function Changeover switchreturn Withoutoff position Without Off positionpoles description 3Pswitching positions Left: 330°Right: 30°IP degree of protection IP40 conforming to IEC 529IP40 conforming to NF C 20-010Complementary switching angle 30 °[Ui] rated insulation voltage 690 V degree of pollution 3 conforming to EN 60947-1690 V degree of pollution 3 conforming to IEC 60947-1rated operational power in W 65000 W AC-23A / 660/690 V 3 phases conforming to EN/IEC 60947-315000 W AC-23A / 220/240 V 1 phase conforming to EN/IEC 60947-322000 W AC-23A / 380/440 V 1 phase conforming to EN/IEC 60947-313000 W AC-3 / 380/440 V 1 phase conforming to EN/IEC 60947-345000 W AC-23A / 380/440 V 3 phases conforming to EN/IEC 60947-330000 W AC-3 / 660/690 V 3 phases conforming to EN/IEC 60947-330000 W AC-3 / 380/440 V 3 phases conforming to EN/IEC 60947-37500 W AC-3 / 220/240 V 1 phase conforming to EN/IEC 60947-35500 W AC-23A / 110 V 1 phase conforming to EN/IEC 60947-315000 W AC-3 / 220/240 V 3 phases conforming to EN/IEC 60947-33700 W AC-3 / 110 V 1 phase conforming to EN/IEC 60947-330000 W AC-23A / 220/240 V 3 phases conforming to EN/IEC 60947-3[Ie] rated operational current AC 100 A AC-21A conforming to EN/IEC 60947-3short-circuit current 15000 Ashort-circuit protection 125 A by cartridge fuse, type gG[Uimp] rated impulse withstand voltage 6 kV conforming to EN 947-16 kV conforming to IEC 947-1contact operation Slow-breakpositive opening Withelectrical connection Captive screw clamp terminals flexible, 2 x 25 mm²Captive screw clamp terminals solid, 2 x 35 mm²tightening torque 2.5 N.mswitching capacity in mA 100000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms)100000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms)100000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms)100000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms)100000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms)100000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms)115000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms)115000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms)115000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms)33000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms)33000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms)33000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms)mechanical durability 300000 cyclesCAD overall width 88 mmCAD overall height 88 mmCAD overall depth 154 mmproduct weight 0.645 kgEnvironment standards EN/IEC 60947-3product certifications CULus 120 V 5 hp 1 phaseCULus 240 V 10 hp 1 phaseCULus 240 V 20 hp 3 phasesCULus 480 V 30 hp 3 phasesprotective treatment TCambient air temperature for operation -25...55 °Cambient air temperature for storage -40...70 °Covervoltage category Class II conforming to IEC 60536Class II conforming to NF C 20-030Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
CertificateSizeAdd to My DocumentsK1 K2 K10 K30 K50 K63 K115 K150 Cam switches (Version 1.0)K1, K2, K10, K30, K50, K63, K115, K150 Cam switches (Version 1.0)K10, K30, K50, K63, K115, K150 Cam switches (Version 1.0)Declaration of conformitySizeAdd to My DocumentsK30, K50, K63, K115, K150 Cam switches (Version 1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
DimensionsFront Mountingesupport panel thickness 0.5 to 5.5 mm / 0.02 to 0.22 in in.a
b
c
D1
mm
in.
mm
in.
mm
in.
mm
in.
114.5
4.51
84
3.31
88
3.46
5.4
0.21
-
Mounting and Clearance
Panel Cut-OutFront MountingD2
D3
G1
mm
in.
mm
in.
mm
in.
6
0.24
13
0.51
68
2.68
-
Technical Description
Link Positions (Factory Mounted)I1Input 1I2Input 2MarkingAngular Position of SwitchSwitching ProgramConvention Used for Switching Program RepresentationContact closed
Contact closed in 2 positions and maintained between the 2 positions
Sealed assembly for auto-maintain control
Overlapping contacts
Spring return position: for a switching angle of 90°, spring return is over 30° after the last position (for a maximum of 3 simultaneous contacts).
Example: