integrated drive ILA with servo motor - 24..36 V - Profibus DP - PCB connector
Show more characteristics >-
Characteristics
Main range of product Lexium integrated driveproduct or component type Motion integrated drivedevice short name ILAmotor type Ac synchronous servo motornumber of motor poles 6network number of phases Single phase[Us] rated supply voltage 24 V36 Vnetwork type DCcommunication interface Integrated Profibus DPlength 145.3 mmwinding type High speed of rotation and medium torqueelectrical connection Printed circuit board connectorholding brake Withoutgear box type Withoutnominal speed 5100 rpm at 24 V7500 rpm at 36 Vnominal torque 0.26 N.mComplementary transmission rate 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000 and 12000 kbaudsmounting support Flangemotor flange size 57 mmnumber of motor stacks 1centring collar diameter 50 mmcentring collar depth 1.6 mmnumber of mounting holes 4mounting holes diameter 5.2 mmcircle diameter of the mounting holes 66.6 mmfeedback type Single turn encodershaft end Untappedsecond shaft Without second shaft endshaft diameter 9 mmshaft length 20 mmsupply voltage limits 18...40 Vcurrent consumption 11000 mA (peak)7500 mA (maximum continuous)associated fuse rating 10 Ainput/output type 4 signals (each be used as input or output)voltage state 0 guaranteed -3...4.5 Vvoltage state 1 guaranteed 15...30 Vdiscrete input current <= 10 mA at 24 V on/STO_A for safety input<= 3 mA at 24 V on/STO_B for safety input2 mA at 24 V for 24 V signal interfacediscrete output voltage 23...25 Vmaximum switching current 100 mA per output200 mA totalprotection type Overload of output voltageSafe torque offShort circuit of the output voltagepeak stall torque 0.43 N.mcontinuous stall torque 0.26 N.mspeed feedback resolution 16384 points/turnaccuracy error +/- 0.05 °rotor inertia 0.1 kg.cm²maximum radial force Fr 89 Nmaximum axial force Fa 104 N (force pressure)104 N (tensile force)service life in hours 20000 h of bearing :marking CEtype of cooling Natural convectionproduct weight 1.4 kgEnvironment standards EN 50347EN 61800-3:2001, second environmentEN 61800-3 : 2001-02EN/IEC 50178EN/IEC 61800-3IEC 60072-1IEC 61800-3, Ed 2product certifications CULTÜVULambient air temperature for operation > 50...65 °C with power derating of 2 % per °C0...50 °C without deratingpermissible ambient air temperature around the device 105 °C (power amplifier)110 °C (motor)ambient air temperature for storage -25...70 °Coperating altitude <= 1000 m without deratingrelative humidity 15...85 % without condensationvibration resistance 20 m/s² (f = 10...500 Hz) for 10 cycles conforming to EN/IEC 60068-2-6shock resistance 150 m/s² for 1000 shocks conforming to EN/IEC 60068-2-29IP degree of protection IP41 shaft bushing conforming to EN/IEC 60034-5IP54 total except shaft bushing conforming to EN/IEC 60034-5Offer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions AvailableContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Danish
- French
- Chinese
- Dutch
- Turkish
- Russian
- Czech
- Italian
- German
- Swedish
User guideSizeAdd to My DocumentsILA1B, ILA1F, ILA1R Lexium Integrated Drives (Version 2.00)CADSizeAdd to My DocumentsCAD files for ILA1B571TB1A0: Lexium ILA1 Integrated drive with servo motor (Version 1.0)Date 2/5/19Size 147 KBDeclaration of conformitySizeAdd to My DocumentsEnd of Life InformationSizeAdd to My DocumentsILS... Lexium Integrated Drive - Range: 3.8A to 5A, Product End-of-Life Instructions (Version 3.0)Date 11/17/17Size 519.8 KBILA... Lexium Integrated Drive - Range: 3.6A to 7A, Product End-of-Life Instructions (Version 1.0)Date 1/28/15Size 553.4 KBREACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Integrated Drive without Holding BrakeDimensions1Accessories: I/O signal insert with industrial connectors2Option: industrial connectors3Earth (ground) terminal4Accessories: cable entries Ø = 3 ... 9 mm/0.12 ... 0.35 in.5Centring hole DIN 332 - DS M3L145.3 mm/5.72 in. -
Connections and Schema
Connection Example with 4 I/O Signals -
Performance Curves
Torque CharacteristicsXSpeed of rotation in rpmYTorque in Nm1.1Max. torque at 24 V1.2Max. torque at 36 V2Continuous torque