Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Schneider Electric GVX750K500HS Image

Range: Galaxy VX

Products

GVX750K500HS

Schneider Electric GVX750K500HS Image
Range: Galaxy VX

Products

GVX750K500HS

Galaxy VX 500kVA N+1 Redundant UPS 400V, Start up 5x8

Show more characteristics >
Add to My Products Remove from My Products

  • Overview
    Description
    Click here to explore the Galaxy VX UPS in 3D!. Highly efficient, scalable, 3-phase power protection with flexible operating modes and ECOnversion™ for large facilities, data centers, and business critical applications.
    Model Name
    Galaxy VX 500kVA N+1 Redundant UPS 400V, Start up 5x8
    Includes
    Installation guide , Network Management Card , Start-Up Service
    Standard Lead Time
    Special Order - Call for Quoted Lead Times
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Cayman Islands , Central African Republic , Chad , Chile , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guinea , Guyana , French Guiana , Haiti , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , Netherlands Antilles , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Papua New Guinea , Peru , Philippines , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uruguay , Uzbekistan , Viet Nam , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Output Power Capacity
    500.0 KW / 500.0 kVA
    Max Configurable Power (Watts)
    500.0 KW / 500.0 kVA
    Nominal Output Voltage
    400 3PH
    Output Frequency (sync to mains)
    50 Hz , 60 Hz
    Other Output Voltages
    380, 415, 440V
    Crest Factor
    3 with THC <5%
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Voltage THD
    < 2% linear load and <3% non-linear load
    Overload Operation
    150% for 1 minute 125% for 10 minutes
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    40 - 70 Hz
    Other Input Voltages
    380 , 415 , 440
    Maximum Input Current
    851 A
    Input Breaker Capacity
    0 A
    Maximum Short Circuit Withstand (Icw)
    100.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Included Battery Modules
    0
    Battery Slots Empty
    0
    Typical recharge time
    0 hour(s)
    RBC Quantity
    0
    Nominal Battery Voltage
    480V
    End of Discharge Battery Voltage
    384 Vdc
    Communications & Management
    Available SmartSlot™ Interface Quantity
    2
    Pre-Installed SmartSlot™ Cards
    AP9635
    Control panel
    7" Touch Screen Display
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Physical
    Maximum Height
    1970.0 mm
    Maximum Width
    3300.0 mm
    Maximum Depth
    900.0 mm
    Rack Height
    0 U
    Net Weight
    2420.0 kg
    Shipping Weight
    3288.0 kg
    Shipping Height
    2150.0 mm
    Shipping Width
    3910.0 mm
    Shipping Depth
    1060.0 mm
    Master Carton Units
    0.0
    Master Carton Weight
    0.0 lbs
    Color
    White
    Units per Pallet
    0.0
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95% non-condensing %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -15 - 40 °C
    Storage Relative Humidity
    0 - 95% non-condensing %
    Storage Elevation
    0-15000 meters
    Audible noise at 1 meter from surface of unit
    69.500 dB
    Online Thermal Dissipation
    82435.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    C-tick , CE , IBC 2012 , IEC 62040-1-1 , IEC 62040-2 , IEC 62040-3 , IEC 62040-4 , ISTA 2B , UL 1778 5th edition , cUL Listed
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Danish
    • Russian
    • French
    • Polish
    • Italian
    • Finnish
    • Chinese
    • Norwegian
    • Dutch
    User guide
    Date
    Size
    Add to My Documents
    Date 10/25/17
    Size 245.5 KB
    Date 4/12/18
    Size 1.8 MB
    Date 6/19/18
    Size 4.2 MB
    Date 8/9/18
    Size 22.1 MB
    CAD
    Date
    Size
    Add to My Documents
    GVX500-1000KH-WD - Galaxy VX UPS 500-625-750-1000kW 400V System Wiring Diagram
    Brochure
    Date
    Size
    Add to My Documents
    Date 8/13/18
    Size 3.1 MB
    Date 8/13/18
    Size 1.3 MB
    Certificate
    Date
    Size
    Add to My Documents
    Specification for tender
    Date
    Size
    Add to My Documents
    CSI 2004/1995 Galaxy VX 500kW Expandable to 1500kVA N+1 Internal Redundancy (400V)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.