Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all TeSys island
Schneider Electric GV2L14 Image

GV2L14

Schneider Electric GV2L14 Image
GV2L14

TeSys GV2 - Circuit breaker - magnetic - 10 A - screw clamp terminals

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys GV2
    device short name
    GV2L
    device application
    Motor
    poles description
    3P
    network type
    AC
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    network frequency
    50/60 Hz conforming to IEC 60947-2
    breaking capacity
    10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity
    100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
    75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    trip unit technology
    Magnetic
    magnetic tripping current
    138 A
    Complementary
    fixing mode
    Clipped on 35 mm symmetrical DIN rail
    Screwed on panel (with 2 x M4 screws)
    operating position
    Any position
    motor power kW
    3 kW at 400/415 V AC 50/60 Hz
    4 kW at 400/415 V AC 50/60 Hz
    4 kW at 500 V AC 50/60 Hz
    7.5 kW at 690 V AC 50/60 Hz
    5.5 kW at 690 V AC 50/60 Hz
    control type
    Rotary knob
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-2
    power dissipation per pole
    1.8 W
    mechanical durability
    100000 cycles
    electrical durability
    100000 cycles for AC-3 at 415 V
    operating rate
    <= 40 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    connections - terminals
    Screw clamp terminals 2 cable(s) 1...6 mm² solid
    Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end cable end
    Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end cable end
    tightening torque
    1.7 N.m on screw clamp terminals
    mechanical robustness
    Shocks 30 Gn conforming to IEC 60068-2-27
    Vibrations 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
    suitability for isolation
    Yes conforming to IEC 60947-1
    phase failure sensitivity
    Yes
    height
    89 mm
    width
    45 mm
    depth
    97 mm
    product weight
    0.33 kg
    Environment
    standards
    EN 60204
    IEC 60947-1
    IEC 60947-2
    NF C 63-120
    NF C 63-650
    NF C 79-130
    VDE 0113
    VDE 0660
    product certifications
    BV
    CCC
    CSA
    DNV
    GL
    LROS (Lloyds register of shipping)
    RINA
    protective treatment
    TH
    IK degree of protection
    IK04
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    0...2000 m
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0631  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Reference contains SVHC above the threshold  -  Go to CaP for more details
    Go to CaP for more details
    Product environmental profile
    Product end of life instructions
    Need no specific recycling operations
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Catalogue TeSys 2019 - Chapitre A6 - Coordination et normes (Version 3.1)
    Catalogue TeSys 2019 - Chapitre B6 - Disjoncteurs (Version 4.0)
    Catalogue TeSys - 2019 - Chapitre A3 - Démarreurs moteurs compacts - TeSys H (Version 3.0)
    TeSys catalogue - 2019 - 2020 - chapter A3 Compact motor starters - TeSys H (Version 5.0)
    TeSys - chapter A2 - Open pre cabled motor starters - tec data - digicat (Version 6.0)
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    TeSys catalogue - 2019 - 2020 - chapter B6 circuit breakers TeSys GV GB (Version 6.0)
    Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)
    TeSys catalogue - 2019 - 2020 - chapter A6 - Circuit breaker + contactor coordination tables and design guidelines (Version 6.1)
    TeSys - chapter A2 - Open pre cabled motor starters - tec data - digicat (Version 6.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for GV2L14: TeSys GV2 - Circuit breaker - magnetic - 10 A - screw clamp terminals (Version 3.0)
    MAGNETIC CIRCUIT BREAKER (Version 1.0)
    Date 9/24/18
    Size 735.5 KB
    Date 9/24/18
    Size 522.7 KB
    Date 9/24/18
    Size 269.9 KB
    Certificate
    Date
    Size
    Add to My Documents
    CCC Certificate TeSys GV2L-GV2LE-GV2ME-GV2P-GV2RT Dijon (Version 1.0)
    CB Certificate TeSys GV2 - GV2L-LE-ME-P-RT Thailand (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    GV2 ME.. Motor circuit-breakers - IS on the box (Version 08)
    GV2AP.. Fixing kit for door interlock mechanism for GV2 P/L (Version 07)
    GV2 P/L Motor circuit-breakers (Version 08)
    Date 4/1/19
    Size 910.7 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP-TeSys GV2 motor circuit breaker (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Performance Curves

    Tripping Curves for GV2L or LE Combined with Thermal Overload Relay LRD or LR2K

    Average Operating Times at 20 °C Related to Multiples of the Setting Current


    1
    3 poles from cold state
    2
    2 poles from cold state
    3
    3 poles from hot state

    Current Limitation on Short-Circuit for GV2L and GV2LE Only (3-Phase 400/415 V)

    Dynamic Stress

    I peak = f (prospective Isc) at 1.05 Ue = 435 V


    1
    Maximum peak current
    2
    32 A
    3
    25 A
    4
    18 A
    5
    14 A
    6
    10 A
    7
    6.3 A
    8
    4 A
    9
    2.5 A
    10
    1.6 A
    11
    Limit of rated ultimate breaking capacity on short-circuit of GV2LE (14, 18, 23, and 25 A ratings).

    Current Limitation on Short-Circuit for GV2L and GV2LE + Thermal Overload Relay LRD or LR2K (3-Phase 400/415 V)

    Dynamic Stress

    I peak = f (prospective Isc) at 1.05 Ue = 435 V


    1
    Maximum peak current
    2
    32 A
    3
    25 A
    4
    18 A
    5
    14 A
    6
    10 A
    7
    6.3 A
    8
    4 A
    9
    2.5 A
    10
    1.6 A
    11
    Limit of rated ultimate breaking capacity on short-circuit of GV2LE (14, 18, 23, and 25 A ratings).

    Thermal Limit on Short-Circuit for GV2L Only

    Thermal Limit in kA2s in the Magnetic Operating Zone

    Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V


    1
    25 A and 32 A
    2
    18 A
    3
    14 A
    4
    10 A
    5
    6.3 A
    6
    4 A
    7
    2.5 A
    8
    1.6 A

    Thermal Limit on Short-Circuit for GV2L and GV2LE + Thermal Overload Relay LRD or LR2K

    Thermal Limit in kA2s in the Magnetic Operating Zone

    Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V


    1
    32 A (GV2LE32)
    2
    25 A and 32 A (GV2L32)
    3
    18 A
    4
    14 A
    5
    10 A
    6
    6.3 A
    7
    4 A
    8
    2.5 A
    9
    1.6 A
    10
    Limit of rated ultimate breaking capacity on short-circuit of GV2 LE (14, 18, 23, and 25 A ratings).


  • Dimensions Drawings

    GV2L

    Dimensions


    X1 Electrical clearance = 40 mm for Ue ≤ 415 V, or 80 mm for Ue = 440 V, or 120 mm for Ue = 500 and 690 V.

    X2 = 40 mm.

    GVAD, AM, AN, AU, AS


    1
    Maximum

    GV2AK00


    Mounting

    On rail AM1 DE200, AM1 ED200 (35 x 15)


    Panel mounted


    On pre-slotted mounting plate AM1 PA


    Adapter Plate GK2AF01


    7.5 mm Height Compensation Plate GV1F03


    Mounting

    Mounting of External Operator GV2APN01, GV2APN02 or GV2APN04 for Motor Circuit Breakers GV2L


    Door cut-out


    (1)
    For IP65 only.

    Mounting of External Operator GVAPH02 for Motor Circuit Breakers GV2L


    b

    Minimum

    Maximum

    GV2 APN●● + GV APH02

    151

    250

    GV2 APN●● + GV APH02 + GV APK11

    250

    445

    Door cut-out


    (1)
    For IP65 only.

    GV2L and GV2LE

    Sets of busbars GV2G445, GV2G454, GV2G472, with terminal block GV2G05


    l

    p

    GV2G445 (4 x 45 mm)

    179

    45

    GV2G454 (4 x 54 mm)

    206

    54

    GV2G472 (4 x 72 mm)

    260

    72

    Number of tap-offs

    a

    5

    6

    7

    8

    GV2G445

    224

    269

    314

    359

    GV2G454

    260

    314

    368

    422

    GV2G472

    332

    404

    476

    548

    Sets of Busbars for GV2L and GV2LE

    Sets of busbars GV2G●●● with terminal block GV1G09


    Sets of busbars GV2G245, GV2G254, GV2GR272


    I

    GV2G245 (2 x 45 mm)

    89

    GV2G254 (2 x 54 mm)

    98

    GV2G272 (2 x 72 mm)

    116

    Set of busbars GV2G554


    Sets of busbars GV2G345 and GV2G354


    I

    GV2G345 (3 x 45 mm)

    134

    GV2G354 (3 x 54 mm)

    152


  • Connections and Schema

    GV2L••



Compare products: /