Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Schneider Electric G55TUPU30HMS Image

    Range: Marine

    G55TUPU30HMS

    Schneider Electric G55TUPU30HMS Image
    Range: Marine

    G55TUPU30HMS

    MGE Galaxy 5500 30kVA 400-415V Single UPS Marine IP22 RAL 7035, Start-up 5X8

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Overview
      Description
      UPS is designed to meet the marine standard requirement.
      Model Name
      MGE Galaxy 5500 30kVA 400-415V Single UPS Marine IP22 RAL 7035, Start-up 5X8
      Includes
      Installation guide , User Manual
      Standard Lead Time
      Special Order - Call for Quoted Lead Times
      Product Distribution
      Afghanistan , Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Cayman Islands , Central African Republic , Chad , Chile , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , East Timor , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , Netherlands Antilles , New Zealand , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Puerto Rico , Qatar , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Trinidad And Tobago , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uruguay , Uzbekistan , Venezuela , Viet Nam , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
      General
      Bypass Connection
      4 wire (3Ph + N) or 5 wire (3Ph + N + G)
      Bypass Voltage Tolerance
      +/-10% settable from +/-4/6/8 and 10%
      Max Bypass Input Current
      43 A
      Bypass Protection Device
      100 A
      Output
      Output Power Capacity
      27.0 KW / 30.0 kVA
      Max Configurable Power (Watts)
      27.0 KW / 30.0 kVA
      Nominal Output Voltage
      400 3PH
      Output Voltage Note
      Configurable for 400 or 415V 3 Phase nominal output voltage
      Output Voltage Distortion
      Less than 2%
      Output Frequency (sync to mains)
      50 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
      Other Output Voltages
      380, 415V
      Crest Factor
      3 : 1
      Double Conversion Online
      Waveform Type
      Sine wave
      Output Voltage Tolerance
      +/- 2% static and 100% load step
      Output Voltage THD
      < 1% linear load and < 2.5% nonlinear load
      Overload Operation
      10 minutes @ 125% and 60 seconds @ 150%
      Required Output Current Protection
      43 A
      Neutral Output Current
      65 A
      Bypass
      Built-in Maintenance Bypass , Built-in Static Bypass , Optional External Bypass
      Input
      Nominal Input Voltage
      400 3PH
      Input Frequency
      45 - 65 Hz
      Input Connections
      Hard Wire 4-wire (3PH + G) , Hard Wire 4-wire (3PH + N)
      Input voltage range for main operations
      323 - 437 (380V) V , 340 - 460 (400V) V , 353 - 477 (415V) V
      Other Input Voltages
      380 , 415
      Maximum Input Current
      60 A
      Input Breaker Capacity
      125 A
      Maximum Short Circuit Withstand (Icw)
      20.0
      Input Total Harmonic Distortion
      Less than 5% for full load
      Type of Input Protection Required
      gL fuse
      Batteries & Runtime
      Battery Type
      No internal battery - uses external battery system
      Included Battery Modules
      0
      Battery Slots Empty
      0
      Typical recharge time
      0 hour(s)
      RBC Quantity
      0
      Communications & Management
      Available SmartSlot™ Interface Quantity
      3
      Pre-Installed SmartSlot™ Cards
      AP9635CH
      Control panel
      Multi-function LCD status and control console
      Emergency Power Off (EPO)
      Yes
      Physical
      Maximum Height
      2210.0 mm
      Maximum Width
      712.0 mm
      Maximum Depth
      855.0 mm
      Rack Height
      0 U
      Net Weight
      488.0 kg
      Shipping Weight
      510.0 kg
      Shipping Height
      2330.0 mm
      Shipping Width
      1080.0 mm
      Shipping Depth
      1200.0 mm
      Master Carton Units
      0.0
      Master Carton Weight
      0.0 lbs
      Units per Pallet
      0.0
      Environmental
      Operating Environment
      0 - 40 °C
      Operating Relative Humidity
      0 - 95 %
      Operating Elevation
      0-999,9 meters
      Storage Temperature
      -20 - 45 °C
      Storage Relative Humidity
      0 - 95 %
      Storage Elevation
      0-12000 meters
      Audible noise at 1 meter from surface of unit
      65.000 dB
      Conformance
      Approvals
      CE , EN/IEC 62040-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , ISO 9001 , TUV , VDE
      Standard warranty
      1 year (parts only) , 1 year on-site repair or replace with factory authorized Start-Up
    • Documents and Downloads

      Language
      • English
      • Spanish
      • Danish
      • Russian
      • French
      • Finnish
      • Chinese
      • German
      • Norwegian
      • Dutch
      User guide
      Date
      Size
      Add to My Documents
      Date 2/8/17
      Size 433.9 KB
      Date 2/17/17
      Size 7.2 MB
      Date 2/17/17
      Size 6.4 MB
      Date 2/17/17
      Size 7.2 MB
      Date 2/17/17
      Size 7.1 MB
      Modbus Register Map for TCP IP- MGE Galaxy 5500
      Date 2/20/17
      Size 3.5 MB
      Date 9/26/17
      Size 1.1 MB
      CAD
      Date
      Size
      Add to My Documents
      G55TUP20K120HMS - MGE Galaxy 5500 20-120kVA 400-415V UPS Marine IP22
      G55TUPU20K120HC1-WD – MGE Galaxy 5500 Offshore & Marine 20-120kVA UPS 1MOD Wiring Diagram
      G55TUPU20K60HBOTC1-SD - MGE Galaxy 5500 Offshore & Marine 20-60kVA UPS 1MOD with Battery & Output XFMR System One Line
      G55TUPU20K60HBC1-SD - MGE Galaxy 5500 Offshore & Marine 20-60kVA UPS 1MOD with Battery Cabinet System One Line
      G55TUP20K120HMS - MGE Galaxy 5500 20-120kVA 400-415V UPS Marine IP22
      Specification for tender
      Date
      Size
      Add to My Documents
      Guide Specification- MGE Galaxy 5500 Marine
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.