You can choose another country to view available products or go to our Global website for company information.
Description |
Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter,conformance coated boards, integrated transformer, and IP 21 Kit protection for harsh environments. UPS supplied without internal batteries. Requires purchase of external battery cabinet. Please click here for additional runtime information.
| |
---|---|---|
Model Name |
MGE Galaxy 300i 20kVA 400V 3:1 with Transformer, Start-up 5x8
| |
Includes |
CD with software , Installation guide , Network Management Card , Start-Up Service , User Manual
| |
Standard Lead Time |
Usually Ships within 2 Weeks
| |
Product Distribution |
Afghanistan , Albania , Algeria , Andorra , Angola , Armenia , Australia , Austria , Azerbaijan , Bahrain , Bangladesh , Belarus , Belgium , Benin , Bhutan , Bosnia And Herzegovina , Botswana , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Central African Republic , Chad , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Philippines , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
|
Output Power Capacity |
16.0 KW / 20.0 kVA
| |
---|---|---|
Max Configurable Power (Watts) |
16.0 KW / 20.0 kVA
| |
Nominal Output Voltage |
230V
| |
Output Voltage Note |
Configurable for 220 : 230 or 240 nominal output voltage
| |
Output Voltage Distortion |
Less than 5%
| |
Output Frequency (sync to mains) |
50/60 Hz +/- 5%
| |
Crest Factor |
2.5 : 1
| |
Double Conversion Online
| ||
Waveform Type |
Sine wave
| |
Output Connections |
(1) Hard Wire 3-wire (H N + G) (Battery Backup)
| |
Output Voltage Tolerance |
+/- 2% static and 100% load step
| |
Output Voltage THD |
< 3% linear load and <5% non-linear load
| |
Overload Operation |
60 seconds @ 120% and 30 seconds @ 145%
| |
Required Output Current Protection |
250 A
| |
Bypass |
Built-in Maintenance Bypass
|
Nominal Input Voltage |
400 3PH
| |
---|---|---|
Input Frequency |
45 - 65 Hz
| |
Input Connections |
Hard Wire 5-wire (3PH + N + G)
| |
Input voltage range for main operations |
340 - 477 V
| |
Input voltage adjustable range for mains operation |
323 - 437 (380V)V , 340 - 460 (400V)V , 357 - 477 (415V)V
| |
Other Input Voltages |
380 , 415
| |
Maximum Input Current |
30 A
| |
Input Breaker Capacity |
63 A
| |
Input Total Harmonic Distortion |
Less than 5% for full load
| |
Type of Input Protection Required |
gL fuse
|
Battery Type |
No internal battery - uses external battery system
| |
---|---|---|
Included Battery Modules |
0
| |
Battery Slots Empty |
0
| |
Typical recharge time |
0 hour(s)
| |
RBC Quantity |
0
|
Available SmartSlot™ Interface Quantity |
0
| |
---|---|---|
Pre-Installed SmartSlot™ Cards |
AP9630
| |
Control panel |
Multi-function LCD status and control console
| |
Emergency Power Off (EPO) |
Yes
|
Maximum Height |
1300.0 mm
| |
---|---|---|
Maximum Width |
500.0 mm
| |
Maximum Depth |
860.0 mm
| |
Rack Height |
0 U
| |
Net Weight |
185.0 kg
| |
Shipping Weight |
211.0 kg
| |
Shipping Height |
1440.0 mm
| |
Shipping Width |
800.0 mm
| |
Shipping Depth |
965.0 mm
| |
Master Carton Units |
0.0
| |
Master Carton Weight |
0.0 lbs
| |
Units per Pallet |
0.0
|
Operating Environment |
0 - 35 °C
| |
---|---|---|
Operating Relative Humidity |
0 - 95 %
| |
Operating Elevation |
0-3000 meters
| |
Storage Temperature |
-10 - 60 °C
| |
Storage Relative Humidity |
0 - 95 %
| |
Storage Elevation |
0-9000 meters
| |
Audible noise at 1 meter from surface of unit |
54.500 dB
| |
Online Thermal Dissipation |
1212.000 BTU/hr
| |
Protection Class |
IP 21
|
Approvals |
CE , EN/IEC 62040-1-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , IEC 61000-4-5 , IEC 62040-2 , TUV , VFI-SS-111
| |
---|---|---|
Standard warranty |
1 year on-site repair or replace with factory authorized Start-Up
|