Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Schneider Electric G3HT80KHB2S Image

    Range: Galaxy 300

    Products

    G3HT80KHB2S

    Schneider Electric G3HT80KHB2S Image
    Range: Galaxy 300

    Products

    G3HT80KHB2S

    Galaxy 300 80kVA 400V 3:3 with 10min Battery (External Cabinet), Start-up 5x8

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Overview
      Description
      Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter and conformance coated boards for harsh environments.
      Model Name
      Galaxy 300 80kVA 400V 3:3 with 10min Battery (External Cabinet), Start-up 5x8
      Includes
      CD with software , Dust filter , Installation guide , Network Management Card , User Manual
      Standard Lead Time
      Usually Ships within 2 Weeks
      Product Distribution
      Albania , Algeria , Andorra , Angola , Argentina , Armenia , Austria , Azerbaijan , Bahrain , Belarus , Belgium , Benin , Bolivia , Bosnia And Herzegovina , Botswana , Bulgaria , Burkina Faso , Burundi , Cameroon , Central African Republic , Chad , Chile , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hungary , Iceland , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Niger , Nigeria , Norway , Oman , Pakistan , Paraguay , Peru , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Switzerland , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Western Sahara , Yemen , Zambia , Zimbabwe
      General
      Bypass Connection
      5 wire (3PH + N + G)
      Output
      Output Power Capacity
      72.0 KW / 80.0 kVA
      Max Configurable Power (Watts)
      72.0 KW / 80.0 kVA
      Nominal Output Voltage
      400 3PH
      Output Voltage Distortion
      Less than 5%
      Output Frequency (sync to mains)
      50/60 Hz +/-1 Hz
      Other Output Voltages
      380, 415V
      Crest Factor
      3 : 1
      Double Conversion Online
      Output Connections
      (1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)
      Output Voltage Tolerance
      +/- 2% static and 100% load step
      Output Voltage THD
      < 3% linear load and <5% non-linear load
      Overload Operation
      10 minutes @ 125% and 30 seconds @ 150%
      Required Output Current Protection
      160 A
      Bypass
      Built-in Static Bypass
      Input
      Nominal Input Voltage
      400 3PH
      Input Frequency
      45 - 65 Hz
      Input Connections
      Hard Wire 5-wire (3PH + N + G)
      Input voltage range for main operations
      340 - 477 V
      Input voltage adjustable range for mains operation
      323 - 437 (380V)V , 340 - 460 (400V)V , 357 - 477 (415V)V
      Other Input Voltages
      380 , 415
      Maximum Input Current
      122 A
      Input Breaker Capacity
      160 A
      Maximum Short Circuit Withstand (Icw)
      16.0
      Input Total Harmonic Distortion
      Less than 5% for full load
      Type of Input Protection Required
      3-pole breaker
      Batteries & Runtime
      Battery Type
      Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
      Included Battery Modules
      0
      Battery Slots Empty
      0
      Typical recharge time
      0 hour(s)
      RBC Quantity
      0
      Nominal Battery Voltage
      +/-192 V (split battery referenced to neutral)
      End of Discharge Battery Voltage
      +/-154 V
      Communications & Management
      Available SmartSlot™ Interface Quantity
      0
      Pre-Installed SmartSlot™ Cards
      AP9630
      Control panel
      Multi-function LCD status and control console
      Emergency Power Off (EPO)
      Yes
      Physical
      Maximum Height
      1900.0 mm
      Maximum Width
      1412.0 mm
      Maximum Depth
      950.0 mm
      Rack Height
      0 U
      Net Weight
      1395.0 kg
      Shipping Weight
      1435.0 kg
      Shipping Height
      1978.0 mm
      Shipping Width
      1649.0 mm
      Shipping Depth
      1120.0 mm
      Master Carton Units
      0.0
      Master Carton Weight
      0.0 lbs
      Units per Pallet
      0.0
      Environmental
      Operating Environment
      0 - 40 °C
      Operating Relative Humidity
      0 - 95% non-condensing %
      Operating Elevation
      0-900 meters
      Storage Temperature
      -15 - 40 °C
      Storage Relative Humidity
      0 - 95% non-condensing %
      Storage Elevation
      0-4500 meters
      Audible noise at 1 meter from surface of unit
      65.000 dB
      Protection Class
      IP 20
      Conformance
      Approvals
      CE , EAC , EN/IEC 62040-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , ISTA 2B
      Standard warranty
      1 year on-site repair or replace with factory authorized Start-Up
      Sustainable Offer Status
      RoHS
      Compliant
    • Documents and Downloads

      Language
      • English
      • Spanish
      • Danish
      • Russian
      • French
      • Polish
      • Finnish
      • Italian
      • German
      • Chinese
      • Norwegian
      • Dutch
      User guide
      Date
      Size
      Add to My Documents
      Date 2/20/17
      Size 1.3 MB
      Date 2/20/17
      Size 1.2 MB
      Date 2/20/17
      Size 1.2 MB
      Date 2/20/17
      Size 1.3 MB
      Date 5/4/17
      Size 1.2 MB
      Date 6/8/17
      Size 1.2 MB
      CAD
      Date
      Size
      Add to My Documents
      G3HT80KHB2S - Galaxy 300 80kVA 3Ph In, 3Ph Out UPS with External Battery, 10Min Runtime
      Brochure
      Date
      Size
      Add to My Documents
      Date 3/31/17
      Size 784.2 KB
      Galaxy 300: la protezione trifase da 10 a 80 kVA
      Date 6/19/18
      Size 509.1 KB
      Specification guide
      Date
      Size
      Add to My Documents
      Date 6/5/16
      Size 990 KB
      Date 9/16/16
      Size 1 MB
      Date 9/21/16
      Size 984.1 KB
      Date 12/17/16
      Size 1,000.7 KB
      Date 2/9/17
      Size 992.2 KB
      Date 9/21/17
      Size 957.9 KB
      Date 11/18/17
      Size 967.2 KB
      Date 6/11/18
      Size 961 KB
      Date 6/15/18
      Size 862.5 KB
      Certificate
      Date
      Size
      Add to My Documents
      Date 2/18/17
      Size 666.1 KB
      Date 6/15/18
      Size 189.3 KB
      Date 6/15/18
      Size 69.7 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.