Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Schneider Electric EMS59201 Image

    Range: Easergy T300

    Modules

    EMS59201

    Schneider Electric EMS59201 Image
    Range: Easergy T300

    Modules

    EMS59201

    Easergy SC150 CT-LPVT/VT: Switch controller - 1/5 A - LPVT/VT sensors

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      Easergy T300
      device short name
      SC150
      Complementary
      product or component type
      MV switch controller
      type of measurement
      Apparent energy
      Current
      Active and reactive power
      Voltage
      Frequency
      Active and reactive energy
      Power factor
      Apparent power
      power quality analysis
      Individual harmonics
      Voltage sag and swell detection
      Voltage magnitude
      Harmonic distortion
      Voltage unbalance
      type of measurement
      Current : class 0.5
      Voltage : class 0.5
      Energy : class 1 conforming to IEC 61557-12
      data recording
      Sag and swell logs
      Current value before fault
      Demand values
      Min/max of instantaneous values
      Sequence of event recording
      Counter
      Harmonics logs
      Event logs
      memory capacity
      4 MB
      synchronisation time between inputs
      1 ms
      control type
      Status : illuminated push-button
      software function
      Assistance in commissioning and operating the installation
      Security/authority verification
      Alarm
      Operating/Status report
      Event log
      Reports and diagrams
      protection type
      Overcurrent : 50/51
      Earth fault : 50N/51N
      Directional phase overcurrent : 67
      Directional earth fault : 67N
      Negative sequence overvoltage : 47
      Undervoltage : 27
      Overvoltage : 59
      Neutral voltage displacement : 59N
      Phase undercurrent : 37
      [Us] rated supply voltage
      12...48 V DC (+/- 20%)
      power consumption in VA
      < 2 VA
      communication port protocol
      IEC 60870-5-104
      communication port support
      2 Ethernet RJ45
      number of inputs
      8 digital conforming to IEC 61131-2 type 3
      measurement current
      1 A
      5 A
      analogue input type
      4 current : 0.01...35 A (0.001 Ohm)
      measurement voltage
      LPVT (single or three phases) : 0...10 V AC at 50/60 Hz
      VTs (single or three phases) : 47...240 V AC at 50/60 Hz
      number of outputs
      Switch : 2 digital (relay)
      maximum switching voltage
      440 V AC
      output voltage
      Motor : 12...127 V DC
      Motor : 90...220 V AC
      continuous output current
      8 A
      breaking capacity
      2000 VA
      Irms rated making capacity
      15 A during 4 s
      Environment
      fixing mode
      Clip-in by DIN rail
      type of installation
      Indoor
      Outdoor in cabinet
      electromagnetic compatibility
      Electrical fast transient/burst immunity test level 4 criteria A conforming to IEC 61000-4-4
      Conducted RF disturbances level 3 criteria A conforming to IEC 61000-4-6
      Conducted disturbance emission level 4 criteria A conforming to IEC 61000-4-16
      100 kHz damped oscillating wave level 3 criteria A conforming to IEC 61000-4-12
      Radiated radio-frequency electromagnetic field immunity test level 4 criteria A conforming to IEC 61000-4-3
      Immunity to voltage dips criteria A conforming to IEC 61000-4-29
      Electrostatic discharge level 4 criteria B conforming to IEC 61000-4-2
      Surge immunity test level 3 criteria A conforming to IEC 61000-4-5
      Magnetic field at power frequency level 5 criteria B conforming to IEC 61000-4-8
      Conducted and radiated emissions class A conforming to EN 55022
      IP degree of protection
      Body : IP2x conforming to IEC 60529
      Front : IP4X conforming to IEC 60529
      IK degree of protection
      IK07 conforming to IEC 62262
      relative humidity
      5...95 % conforming to IEC 60068-2-30
      mechanical robustness
      Vibrations 10...2000 Hz 1 gn 10 cycles conforming to IEC 60068-2-6
      Bumps 10 gn 16 ms 1000 bumps non energized conforming to IEC 60068-2-29
      Shocks 10 gn 11 ms 3 pulses in operation conforming to IEC 60068-2-27
      ambient air temperature for storage
      -40...85 °C
      ambient air temperature for operation
      -40...70 °C
      operating altitude
      3000 m
      product certifications
      CE
      standards
      IEC 60255-27
      IEC 61557-12
      IEC 62586-1
      IEC 61850
      IEC 61000-4-30 (class S)
      height
      140 mm
      width
      45 mm
      depth
      140 mm
      product weight
      0.515 kg
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1635  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Available End of life manual
    • Documents and Downloads

      Language
      • English
      • French
      Catalogue
      Date
      Size
      Add to My Documents
      Date 6/19/18
      Size 4.7 MB
      User guide
      Date
      Size
      Add to My Documents
      Date 3/13/18
      Size 2.2 MB
      Date 3/13/18
      Size 2.2 MB
      Date 5/31/18
      Size 1.8 MB
      Date 3/13/18
      Size 6.2 MB
      Date 5/31/18
      Size 6.1 MB
      Date 3/9/18
      Size 1.7 MB
      End of life manual
      Date
      Size
      Add to My Documents
      Date 3/29/18
      Size 541 KB
      Product environmental
      Date
      Size
      Add to My Documents
      Date 3/29/18
      Size 469.1 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.