Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Schneider Electric CV3BK3V0ZM522 Image

    Range: TeSys B

    Bar-mounted contactors

    CV3BK3V0ZM522

    Schneider Electric CV3BK3V0ZM522 Image
    Range: TeSys B

    Bar-mounted contactors

    CV3BK3V0ZM522

    contactor TeSys CV3BK - 3 pole - AC-3 1000 V 500A - coil 220 V AC

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Main
      range
      TeSys
      product name
      TeSys B
      product or component type
      Contactor
      device short name
      CV3BK
      contactor application
      Motor
      Resistive circuits, heating, lighting
      utilisation category
      AC-1
      AC-3
      control circuit type
      AC
      poles description
      3P
      pole contact composition
      3 NO
      [Ie] rated operational current
      500 A AC for control circuit
      460 A AC AC-3 for power circuit
      motor power kW
      250 kW at 400 V AC AC-3
      current rating code of contactor
      BK
      auxiliary contact composition
      2 NO + 2 NC
      [Uc] control circuit voltage
      220 V AC 50 Hz
      Complementary
      auxiliary contacts type
      Type instantaneous (2 NO + 2 NC)
      control circuit voltage limits
      0.85...1.1 Uc at (<= 55 °C) operational 50 Hz
      0.5...0.7 Uc at (<= 55 °C) drop-out 50 Hz
      [Ui] rated insulation voltage
      1000 V - conforming to IEC 60947-4
      connections - terminals
      Control circuit : cable with lug 1 cable 185 mm²
      Power circuit : bolted connection
      tightening torque
      Control circuit : 1.2 N.m - on with cable end - cable 2...4 mm²
      Control circuit : 1.2 N.m - on with cable end - cable 1...4 mm²
      Control circuit : 1.2 N.m - on without cable end - cable 2...6 mm²
      Control circuit : 1.2 N.m - on without cable end - cable 1...6 mm²
      Power circuit : 35 N.m - on cable with lug - cable 185 mm²
      [Ue] rated operational voltage
      1000 V AC 50 Hz for control circuit
      [Ith] conventional free air thermal current
      80 A at <= 40 °C for control circuit
      Irms rated making capacity
      4600 A at 1000 V AC for control circuit conforming to IEC 60947-4-1
      rated breaking capacity
      3800 A at <= 440 V for control circuit conforming to IEC 60947-4-1
      3700 A at 500 V for control circuit conforming to IEC 60947-4-1
      3600 A at 660/690 V for control circuit conforming to IEC 60947-4-1
      2600 A at 1000 V for control circuit conforming to IEC 60947-4-1
      [Icw] rated short-time withstand current
      4000 A at <= 40 °C 1 s control circuit
      4000 A at <= 40 °C 5 s control circuit
      3680 A at <= 40 °C 10 s control circuit
      2200 A at <= 40 °C 30 s control circuit
      1800 A at <= 40 °C 60 s control circuit
      1100 A at <= 40 °C 180 s control circuit
      720 A at <= 40 °C 600 s control circuit
      associated fuse rating
      315 A aM at <= 400 V for control circuit
      400 A gG at <= 400 V for control circuit
      average impedance
      0.3 mOhm at 50 Hz - Ith 80 A for control circuit
      power dissipation per pole
      63 W AC-3
      75 W AC-1
      inrush power in VA
      570 VA 50 Hz 3P
      hold-in power consumption in VA
      80 VA 50 Hz
      operating time
      35 ms contactor closed AC
      14 ms contactor open AC
      mechanical durability
      10000000 cycles
      operating rate
      <= 120 cyc/mn at <= 55 °C
      rated operational power in W
      4000 W at 440/500 V - electrical durability: 1000000 cycles - for control circuit
      1500 W at 440/500 V - electrical durability: 3000000 cycles - for control circuit
      500 W at 440/500 V - electrical durability: 10000000 cycles - for control circuit
      Environment
      standards
      IEC 60947-4
      EN 60947-4
      product certifications
      CSA
      IP degree of protection
      IP00 conforming to IEC 60529
      protective treatment
      TC
      ambient air temperature for operation
      -5...55 °C
      ambient air temperature for storage
      -60...80 °C
      operating altitude
      2000 m