Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Share

    Copy Cancel
    Schneider Electric CV3BK3V0ZM522 Image

    Range: TeSys B

    Bar-mounted contactors

    CV3BK3V0ZM522

    Schneider Electric CV3BK3V0ZM522 Image
    Range: TeSys B

    Bar-mounted contactors

    CV3BK3V0ZM522

    contactor TeSys CV3BK - 3 pole - AC-3 1000 V 500A - coil 220 V AC

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      TeSys
      range
      TeSys
      product name
      TeSys B
      product or component type
      Contactor
      device short name
      CV3BK
      contactor application
      Motor
      Resistive circuits, heating, lighting
      utilisation category
      AC-1
      AC-3
      control circuit type
      AC
      poles description
      3P
      pole contact composition
      3 NO
      [Ie] rated operational current
      500 A AC for control circuit
      460 A AC AC-3 for power circuit
      motor power kW
      250 kW at 400 V AC AC-3
      current rating code of contactor
      BK
      auxiliary contact composition
      2 NO + 2 NC
      [Uc] control circuit voltage
      220 V AC 50 Hz
      Complementary
      auxiliary contacts type
      Type instantaneous (2 NO + 2 NC)
      control circuit voltage limits
      0.85...1.1 Uc at (<= 55 °C) operational 50 Hz
      0.5...0.7 Uc at (<= 55 °C) drop-out 50 Hz
      [Ui] rated insulation voltage
      1000 V - conforming to IEC 60947-4
      connections - terminals
      Control circuit : cable with lug 1 cable 185 mm²
      Power circuit : bolted connection
      tightening torque
      Control circuit : 1.2 N.m - on with cable end - cable 2...4 mm²
      Control circuit : 1.2 N.m - on with cable end - cable 1...4 mm²
      Control circuit : 1.2 N.m - on without cable end - cable 2...6 mm²
      Control circuit : 1.2 N.m - on without cable end - cable 1...6 mm²
      Power circuit : 35 N.m - on cable with lug - cable 185 mm²
      [Ue] rated operational voltage
      1000 V AC 50 Hz for control circuit
      [Ith] conventional free air thermal current
      80 A at <= 40 °C for control circuit
      Irms rated making capacity
      4600 A at 1000 V AC for control circuit conforming to IEC 60947-4-1
      rated breaking capacity
      3800 A at <= 440 V for control circuit conforming to IEC 60947-4-1
      3700 A at 500 V for control circuit conforming to IEC 60947-4-1
      3600 A at 660/690 V for control circuit conforming to IEC 60947-4-1
      2600 A at 1000 V for control circuit conforming to IEC 60947-4-1
      [Icw] rated short-time withstand current
      4000 A at <= 40 °C 1 s control circuit
      4000 A at <= 40 °C 5 s control circuit
      3680 A at <= 40 °C 10 s control circuit
      2200 A at <= 40 °C 30 s control circuit
      1800 A at <= 40 °C 60 s control circuit
      1100 A at <= 40 °C 180 s control circuit
      720 A at <= 40 °C 600 s control circuit
      associated fuse rating
      315 A aM at <= 400 V for control circuit
      400 A gG at <= 400 V for control circuit
      average impedance
      0.3 mOhm at 50 Hz - Ith 80 A for control circuit
      power dissipation per pole
      63 W AC-3
      75 W AC-1
      inrush power in VA
      570 VA 50 Hz 3P
      hold-in power consumption in VA
      80 VA 50 Hz
      operating time
      35 ms contactor closed AC
      14 ms contactor open AC
      mechanical durability
      10000000 cycles
      operating rate
      <= 120 cyc/mn at <= 55 °C
      rated operational power in W
      4000 W at 440/500 V - electrical durability: 1000000 cycles - for control circuit
      1500 W at 440/500 V - electrical durability: 3000000 cycles - for control circuit
      500 W at 440/500 V - electrical durability: 10000000 cycles - for control circuit
      Environment
      standards
      IEC 60947-4
      EN 60947-4
      product certifications
      CSA
      IP degree of protection
      IP00 conforming to IEC 60529
      protective treatment
      TC
      ambient air temperature for operation
      -5...55 °C
      ambient air temperature for storage
      -60...80 °C
      operating altitude
      2000 m