    TeSys K control relay - 3 NO + 1 NC - <= 690 V - 230 V AC coil

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      TeSys K control relay
      range
      TeSys
      product name
      TeSys CAK
      product or component type
      Control relay
      device short name
      CA2K
      contactor application
      Control circuit
      utilisation category
      DC-13
      AC-15
      pole contact composition
      3 NO + 1 NC
      [Ue] rated operational voltage
      <= 690 V <= 400 Hz
      control circuit type
      AC 50/60 Hz
      [Uc] control circuit voltage
      230 V AC 50/60 Hz
      Complementary
      [Ith] conventional free air thermal current
      10 A at <= 50 °C
      Irms rated making capacity
      110 A conforming to IEC 60947
      associated fuse rating
      10 A gG conforming to IEC 60947
      10 A gG conforming to VDE 0660
      [Ui] rated insulation voltage
      600 V conforming to CSA C22.2 No 14
      600 V conforming to UL 508
      690 V conforming to BS 5424
      690 V conforming to IEC 60947
      690 V conforming to NF C 20-040
      750 V conforming to VDE 0110 group C
      mounting support
      Rail
      Plate
      connections - terminals
      Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
      Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - with cable end
      Screw clamp terminals 1 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end
      Screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - without cable end
      tightening torque
      0.8 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      0.8 N.m - on screw clamp terminals - with screwdriver Philips No 2 6 mm
      control circuit voltage limits
      0.8...1.15 Uc at 50 °C operational
      0.2...0.75 Uc at 50 °C drop-out
      operating time
      10...20 ms coil de-energisation and NO opening
      5...15 ms coil energisation and NC opening
      10...20 ms coil energisation and NO closing
      15...25 ms coil de-energisation and NC closing
      mechanical durability
      10 Mcycles
      operating rate
      3600 cyc/h
      immunity to microbreaks
      2 ms
      inrush power in VA
      30 VA at 20 °C
      hold-in power consumption in VA
      4.5 VA at 20 °C
      heat dissipation
      1.3 W
      minimum switching voltage
      17 V
      minimum switching current
      5 mA
      non overlap distance
      0.5 mm
      insulation resistance
      > 10 MOhm
      height
      58 mm
      width
      45 mm
      depth
      57 mm
      product weight
      0.235 kg
      compatibility code
      CA2K
      Environment
      standards
      BS 5424
      IEC 60947
      NF C 63-110
      VDE 0660
      EN 60335-1
      product certifications
      CSA
      UL
      IP degree of protection
      IP20
      protective treatment
      TC conforming to IEC 60068
      TC conforming to DIN 50016
      ambient air temperature for operation
      -25...50 °C
      ambient air temperature for storage
      -50...80 °C
      operating altitude
      2000 m without derating in temperature
      flame retardance
      V1 conforming to UL 94
      Requirement 2 conforming to NF F 16-101
      Requirement 2 conforming to NF F 16-102
      mechanical robustness
      Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
      Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
      Vibrations contactor open 2 Gn, 5...300 Hz IEC 60068-2-6
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)