processor module M340 - max 1024 discrete + 256 analog I/O

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon M340 automation platform
    product or component type
    Processor module
    number of racks
    4
    number of slots
    11
    discrete I/O processor capacity
    1024 I/O multi-rack configuration
    704 I/O single-rack configuration
    analogue I/O processor capacity
    256 I/O multi-rack configuration
    66 I/O single-rack configuration
    number of application specific channel
    36
    monitoring
    Diagnostic counters Modbus
    Event counters Modbus
    Complementary
    control channels
    Programmable loops
    motion control
    Independent axis CANopen
    integrated connection type
    USB port 12 Mbit/s
    CANopen master bus SUB-D 9 20 kbit/s...1 Mbit/s 2 twisted shielded pairs
    Non isolated serial link RJ45 character mode asynchronous in baseband RS232C full duplex 0.3...19.2 kbit/s 2 twisted shielded pairs
    Non isolated serial link RJ45 character mode asynchronous in baseband RS485 half duplex 0.3...19.2 kbit/s 1 twisted shielded pair
    Non isolated serial link RJ45 Modbus master/slave RTU/ASCII asynchronous in baseband RS232C half duplex 0.3...19.2 kbit/s 1 twisted shielded pair
    Non isolated serial link RJ45 Modbus master/slave RTU/ASCII asynchronous in baseband RS485 half duplex 0.3...19.2 kbit/s 1 twisted shielded pair
    communication module processor capacity
    2 Ethernet communication module
    4 AS-Interface module
    embedded communication service
    Network management (NMT) CANopen
    Process Data Object (PDO) CANopen
    Service Data Object (SDO) CANopen
    Special functions (SYNC, EMCY, TIME) CANopen
    transmission rate
    1 Mbit/s 0...20 m 0...0.6 m
    125 kbit/s 0...500 m 0...10 m
    20 kbit/s 0...2500 m 0...300 m
    250 kbit/s 0...250 m 0...10 m
    50 kbit/s 0...1000 m 0...120 m
    500 kbit/s 0...100 m 0...10 m
    800 kbit/s 0...40 m 0...6 m
    bus type
    CANopen M20 DS 301 V4.02 devices linked by daisy-chaining or tap junctions CSMA/CA
    CANopen M20 DS 303-2 devices linked by daisy-chaining or tap junctions CSMA/CA
    CANopen M20 DS 405 devices linked by daisy-chaining or tap junctions CSMA/CA
    number of slave
    63 CANopen
    number of devices per segment
    32 character mode
    32 Modbus
    16 <= 205 m CANopen
    32 <= 185 m CANopen
    64 <= 160 m CANopen
    number of devices
    2 point-to-point character mode
    2 point-to-point Modbus
    bus length
    0...10 m serial link non isolated character mode segment
    0...10 m serial link non isolated Modbus segment
    0...1000 m serial link isolated character mode segment
    0...1000 m serial link isolated Modbus segment
    0...15 m character mode point-to-point
    0...15 m Modbus point-to-point
    tap links length
    <= 15 m serial link non isolated character mode segment
    <= 15 m serial link non isolated Modbus segment
    <= 40 m serial link isolated character mode segment
    <= 40 m serial link isolated Modbus segment
    number of addresses
    248 character mode
    248 Modbus
    requests
    1 K data bytes per request character mode
    252 data bytes per RTU request Modbus
    504 data bytes per ASCII request Modbus
    control parameter
    One CRC on each frame (RTU) Modbus
    One LRC on each frame (ASCII) character mode
    One LRC on each frame (ASCII) Modbus
    memory description
    4096 kB internal RAM
    256 kB internal RAM for data
    3584 kB internal RAM for program constants and symbols
    Supplied memory card (BMXRMS008MP) for backup of programs, constants, symbols and data
    maximum size of object areas
    256 kB unlocated internal data
    32634 %Mi located internal bits
    default size of object areas
    1024 %MWi internal words located internal data
    256 %KWi constant words located internal data
    512 %Mi located internal bits
    application structure
    1 cyclic/periodic master task
    1 periodic fast task
    64 event tasks
    No auxiliary task
    execution time per instruction
    0.12 µs Boolean
    0.17 µs double-length words
    0.25 µs single-length words
    1.16 µs floating points
    number of instructions per ms
    6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
    8.1 Kinst/ms 100 % Boolean
    system overhead
    0.13 ms fast task
    0.7 ms master task
    current consumption
    90 mA 24 V DC
    supply
    Internal power supply via rack
    marking
    CE
    status LED
    1 LED green integrated machine/installation bus operational (CAN RUN)
    1 LED green processor running (RUN)
    1 LED red I/O module fault (I/O)
    1 LED red integrated machine/installation bus fault (CAN ERR)
    1 LED red memory card fault (CARD ERR)
    1 LED red processor or system fault (ERR)
    1 LED yellow activity on Modbus (SER COM)
    product weight
    0.21 kg
    Environment
    ambient air temperature for operation
    0...60 °C
    relative humidity
    10...95 % without condensation
    IP degree of protection
    IP20
    protective treatment
    TC
    directives
    2012/19/EU - WEEE directive
    2014/30/EU - electromagnetic compatibility
    2014/35/EU - low voltage directive
    standards
    EN 61000-6-2
    EN 61000-6-4
    EN 61131-2
    EN 61010-2-201
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Modules Mounted on Racks
    Dimensions


    (1)
    With removable terminal block (cage, screw or spring).
    (2)
    With FCN connector.
    (3)
    On AM1 ED rail: 35 mm wide, 15 mm deep. Only possible with BMXXBP0400/0400H/0600/0600H/0800/0800H rack.

    Rack references

    a in mm

    a in in.

    BMXXBP0400 and BMXXBP0400H

    242.4

    09.54

    BMXXBP0600 and BMXXBP0600H

    307.6

    12.11

    BMXXBP0800 and BMXXBP0800H

    372.8

    14.68

    BMXXBP1200 and BMXXBP1200H

    503.2

    19.81