    range of product
    Modicon X80
    product or component type
    Relay discrete output module
    product specific application
    For severe environments
    discrete output number
    8 conforming to EN/IEC 61131-2
    discrete output logic
    Positive
    discrete output voltage
    24...240 V 19...264 V AC
    24...125 V 5...150 V DC
    Complementary
    electrical connection
    20 ways terminal block
    network frequency
    50/60 Hz
    network frequency limits
    47...63 Hz
    sensor power supply
    5...150 V
    19...264 V
    [Ith] conventional free air thermal current
    2 A
    1.2 A
    insulation resistance
    > 10 MOhm 500 V DC
    power dissipation in W
    <= 3.6 W
    response time on output
    <= 13 ms deactivation
    <= 10 ms activation
    typical current consumption
    40 mA at 3.3 V DC
    101 mA at 24 V DC
    MTBF reliability
    2683411 H
    protection type
    External overvoltage protection, inductive AC network
    External overvoltage protection, inductive DC network
    External overload protection
    External short-circuit protection
    output overload protection
    Use 1 fast blow fuse per channel or group of channel
    output overvoltage protection
    Use discharge diode on each output DC
    Use RC circuit on each output AC
    Use ZNO surge limiter on each output AC
    output short-circuit protection
    Use 1 fast blow fuse per channel or group of channel
    minimum switching current
    1 mA 5 V DC
    electrical durability
    200000 cycles AC-12 48 VA 24 V at -25...60 °C
    200000 cycles AC-12 28.8 VA 24 V at 70 °C
    300000 cycles AC-12 48 VA 48 V at -25...60 °C
    300000 cycles AC-12 28.8 VA 48 V at 70 °C
    150000 cycles AC-12 96 VA 48 V at -25...60 °C
    150000 cycles AC-12 57.6 VA 48 V at 70 °C
    300000 cycles AC-12 110 VA 100...120 V at -25...60 °C
    300000 cycles AC-12 66 VA 100...120 V at 70 °C
    150000 cycles AC-12 220 VA 100...120 V at -25...60 °C
    150000 cycles AC-12 132 VA 100...120 V at 70 °C
    300000 cycles AC-12 220 VA 200...250 V at -25...60 °C
    300000 cycles AC-12 132 VA 200...250 V at 70 °C
    150000 cycles AC-12 500 VA 200...250 V at -25...60 °C
    150000 cycles AC-12 300 VA 200...250 V at 70 °C
    700000 cycles AC-15 10 VA 24 V 0.4 at -25...60 °C
    700000 cycles AC-15 6 VA 24 V 0.4 at 70 °C
    500000 cycles AC-15 24 VA 24 V 0.4 at -25...60 °C
    500000 cycles AC-15 14.4 VA 24 V 0.4 at 70 °C
    200000 cycles AC-15 48 VA 24 V 0.4 at -25...60 °C
    200000 cycles AC-15 28.8 VA 24 V 0.4 at 70 °C
    700000 cycles AC-15 10 VA 48 V 0.4 at -25...60 °C
    700000 cycles AC-15 6 VA 48 V 0.4 at 70 °C
    500000 cycles AC-15 24 VA 48 V 0.4 at -25...60 °C
    500000 cycles AC-15 14.4 VA 48 V 0.4 at 70 °C
    300000 cycles AC-15 48 VA 48 V 0.4 at -25...60 °C
    300000 cycles AC-15 28.8 VA 48 V 0.4 at 70 °C
    100000 cycles AC-15 96 VA 48 V 0.4 at -25...60 °C
    100000 cycles AC-15 57.6 VA 48 V 0.4 at 70 °C
    1000000 cycles AC-15 10 VA 100...120 V 0.4 at -25...60 °C
    1000000 cycles AC-15 6 VA 100...120 V 0.4 at 70 °C
    300000 cycles AC-15 50 VA 100...120 V 0.4 at -25...60 °C
    300000 cycles AC-15 30 VA 100...120 V 0.4 at 70 °C
    200000 cycles AC-15 110 VA 100...120 V 0.4 at -25...60 °C
    200000 cycles AC-15 66 VA 100...120 V 0.4 at 70 °C
    70000 cycles AC-15 220 VA 100...120 V 0.4 at -25...60 °C
    70000 cycles AC-15 132 VA 100...120 V 0.4 at 70 °C
    1000000 cycles AC-15 10 VA 200...250 V 0.4 at -25...60 °C
    1000000 cycles AC-15 6 VA 200...250 V 0.4 at 70 °C
    500000 cycles AC-15 50 VA 200...250 V 0.4 at -25...60 °C
    500000 cycles AC-15 30 VA 200...250 V 0.4 at 70 °C
    200000 cycles AC-15 110 VA 200...250 V 0.4 at -25...60 °C
    200000 cycles AC-15 66 VA 200...250 V 0.4 at 70 °C
    150000 cycles AC-15 220 VA 200...250 V 0.4 at -25...60 °C
    150000 cycles AC-15 132 VA 200...250 V 0.4 at 70 °C
    200000 cycles DC-12 24 W 24 V at -25...60 °C
    200000 cycles DC-12 14.4 W 24 V at 70 °C
    150000 cycles DC-12 48 W 24 V at -25...60 °C
    150000 cycles DC-12 28.8 W 24 V at 70 °C
    150000 cycles DC-12 40 W 48...60 V at -25...60 °C
    150000 cycles DC-12 24 W 48...60 V at 70 °C
    100000 cycles DC-12 45 W 100...125 V at -25...60 °C
    60000 cycles DC-12 45 W 100...125 V at 70 °C
    100000 cycles DC-13 10 W 24 V at -25...60 °C
    100000 cycles DC-13 6 W 24 V at 70 °C
    60000 cycles DC-13 24 W 24 V at -25...60 °C
    60000 cycles DC-13 14.4 W 24 V at 70 °C
    40000 cycles DC-13 48 W 24 V at -25...60 °C
    40000 cycles DC-13 28.8 W 24 V at 70 °C
    40000 cycles DC-13 40 W 48...60 V at -25...60 °C
    40000 cycles DC-13 24 W 48...60 V at 70 °C
    100000 cycles DC-13 15 W 100...125 V at -25...60 °C
    40000 cycles DC-13 15 W 100...125 V at 70 °C
    status LED
    1 LED per channel green for channel diagnostic
    1 LED red for ERR
    1 LED red for I/O
    1 LED green for RUN
    product weight
    0.169 kg
    Environment
    IP degree of protection
    IP20
    product certifications
    CSA
    RCM
    UL
    EAC
    CE
    standards
    EN/IEC 61131-2
    EN/IEC 61010-2-201
    CSA C22.2 No 61010-2-201
    UL 61010-2-201
    dielectric strength
    1780 V AC at 50/60 Hz 1 min
    vibration resistance
    3 gn
    shock resistance
    30 gn
    ambient air temperature for storage
    -40...85 °C
    ambient air temperature for operation
    -25...70 °C
    relative humidity
    0...95 % without condensation 60 °C
    protective treatment
    Conformal coating
    environmental characteristic
    Gas resistant class Gx
    Gas resistant class 3C4
    Dust resistant class 3S4
    Sand resistant class 3S4
    Salt resistant level 2
    Mold growth resistant class 3B2
    Fungal spore resistant class 3B2
    operating altitude
    0...2000 m
    2000...5000 m (with derating factor)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Catalogue Plate-forme Modicon X80 I/O - Version Française Ed. 04/2018 (Version 9.0)
    Modicon X80 Automation platform - Catalogue (Version 9.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for BMXDRA0815H: discrete module X80 - 8 NO Type A - Isolated relays - 125 V DC/250 V AC - severe (Version 2.0)
    Certificate
    Date
    Size
    Add to My Documents
    CSA 225844 - M340_M580_X80 (Version 1.0)
    Date 5/15/19
    Size 242.2 KB
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 5/15/19
    Size 395.6 KB
    ATEX IECEx - Zone 2 & 22 - M340_M580_X80 (Version 1.0)
    EAC - M340_M580_X80 (Version 1.0)
    Date 5/15/19
    Size 2.2 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    EU Declaration of Conformity - M340_M580_X80 (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Date 1/29/19
    Size 181.4 KB
    DNV-GL_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    LR_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    KRS Marine Certificate Modicon M340 X80 PLC (Version 1.0)
    BV Marine Certificate M340_M580_X80 PLCs (Version 1.0)