
enclosed variable speed drive ATV71 Plus-LH - 110 KW - 400V - IP23- low harmonic
Show more characteristics >-
Characteristics
Main range of product Altivar 71 Plus-LHproduct or component type Variable speed drivedevice short name ATV71product destination Asynchronous motorsSynchronous motorsassembly style In floor-standing enclosure compact versionkit composition A line chokeA switch and fast-acting fusesAn IP65 remote mounting kit for graphic display terminalTerminals/bars for motor connectionA wired ready-assembled Schneider Spacial SF enclosureActive infeed converterControl transformer 230 V ACPower supply 24 V DCClean power filter with integrated EMC filterATV71HC11N4 standard drive IP00Complementary EMC filter Integratednetwork number of phases 3 phases[Us] rated supply voltage 380...415 V (+/- 10 %)supply voltage limits 342...457 Vsupply frequency 50...60 Hz (+/- 5 %)network frequency limits 47.5...63 Hzmotor power kW 110 kW 3 phases at 380...415 Vline current 177 A at 400 V 3 phases 110 kWapparent power 123 kVA at 400 V 3 phases 110 kWprospective line Isc 100 kA with external fuses100 kA with option circuit breakercontinuous output current 215 A 2.5 kHz at 400 V 3 phasesmaximum transient current 323 A for 60 s at 400 V 3 phasesspeed drive output frequency 0.1...500 Hznominal switching frequency 2.5 kHzswitching frequency 2...8 kHz adjustable2.5...8 kHz with derating factorspeed range 1...100 in open-loop mode, without speed feedbackspeed accuracy +/- 0.01 % of nominal speed (0.2 Tn to Tn) in closed-loop mode with encoder feedback+/- 10 % of nominal slip (0.2 Tn to Tn) without speed feedbacktorque accuracy +/- 15 % in open-loop mode, without speed feedback+/- 5 % in closed-loop mode with encoder feedbacktransient overtorque 170 % of nominal motor torque (+/- 10 %) 60 s220 % of nominal motor torque (+/- 10 %) 2 sbraking torque 100 % continuous120 % for 60 secondsasynchronous motor control profile ENA (Energy adaptation) system for unbalanced loadsVoltage/frequency ratio (2 or 5 points)Vector control with/without speed feedbacksynchronous motor control profile Vector control without sensor, standardVector control with sensor, standardregulation loop Adjustable PI regulatormotor slip compensation AdjustableAutomatic whatever the loadCan be suppressedNot available in voltage/frequency ratio (2 or 5 points)overvoltage category Class 3 conforming to EN 50178local signalling LCD display unit with operation function, status and configuration - mounted in the front dooroutput voltage <= power supply voltageisolation Between power and control terminalstype of cable IEC cable at 40 °C copper 70 °C PVCelectrical connection Terminal, clamping capacity: 2.5 mm² AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) for entry from the bottomTerminal M10, clamping capacity: 2 x 150 mm² (L1/R, L2/S, L3/T) for entry from the bottomTerminal M12, clamping capacity: 2 x 240 mm² (U/T1, V/T2, W/T3) for entry from the bottommotor recommanded cable cross section 3 x 120 mm²short-circuit protection 250 A for fuse 3 gI power supply upstreamsupply External supply at 24 V DC 19...30 V 1 A 30 WInternal supply for reference potentiometer at 10 V DC 10...11 V <= 10 mAInternal supply at 24 V DC 21...27 V <= 100 mAanalogue input number 2analogue input type Bipolar differential voltage (AI1-/Al1+) +/- 10 V DC at 24 V max, duration: 1.5...2.5 ms) 11 bits + signSoftware-configurable voltage (AI2) 0...10 V DC at 24 V max 30 kOhm, duration: 1.5...2.5 ms) 11 bitsSoftware-configurable current (AI2) 0...20 mA/4...20 mA 250 Ohm, duration: 1.5...2.5 ms) 11 bitsanalogue output number 1analogue output type Software-configurable voltage (AO1) 0...10 V DC at 470 Ohm, duration: 1.5...2.5 ms 10 bitsSoftware-configurable current (AO1) 0...20 mA/4...20 mA at 500 Ohm, duration: 1.5...2.5 ms 10 bitsdiscrete output number 1discrete output type Configurable relay logic (R1A, R1B, R1C) NO/NC, response time: 6.5...7.5 ms - electrical durability: 100000 cyclesminimum switching current 3 mA at 24 V DC (configurable relay logic)maximum switching current 5 A at 250 V AC - load type: resistive cos phi = 1 configurable relay logic5 A at 30 V DC - load type: resistive L/R = 0 ms configurable relay logic2 A at 250 V AC - load type: inductive cos phi = 0.4 configurable relay logic2 A at 30 V DC - load type: inductive L/R = 7 ms configurable relay logicdiscrete input number 6discrete input type Programmable (LI1...LI4) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5...2.5 ms)Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5...2.5 ms)Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhmdiscrete input logic Positive logic (source) (LI1...LI6) voltage (state 0): 0...5 V voltage (state 1): 11...30 VNegative logic (sink) (LI1...LI6) voltage (state 0): 16...30 V voltage (state 1): 0...10 VPositive logic (source) (PWR) voltage (state 0): 0...2 V voltage (state 1): 17...30 Vacceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 sS, U or customizedbraking to standstill By regenerative braking with active front endprotection type Overheating protection for driveShort-circuit between motor phases for driveOvercurrent between output phases and earth for driveOvervoltages on the DC bus for driveAgainst exceeding limit speed for driveLine supply undervoltage for driveLine supply overvoltage for driveAgainst input phase loss for driveThermal protection for motorMotor phase break for motorPower removal for drivedielectric strength 3535 V DC between earth and power terminals5092 V DC between control and power terminalsinsulation resistance > 1 mOhm at 500 V DC for 1 minute to earthfrequency resolution 0.1 Hz for display unit0.024/50 Hz for analog inputcommunication port protocol CANopenModbusconnector type 1 RJ45 - communication protocol: Modbus on front face1 RJ45 - communication protocol: Modbus on terminalMale SUB-D 9 on RJ45 - communication protocol: CANopenphysical interface 2-wire RS 485 - communication protocol: Modbustransmission frame RTU - communication protocol: Modbustransmission rate 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps - communication protocol: CANopen4800 bps, 9600 bps, 19200 bps, 38.4 Kbps - communication protocol: Modbus on terminal9600 bps, 19200 bps - communication protocol: Modbus on front facedata format 8 bits, 1 stop, even parity - communication protocol: Modbus on front face8 bits, odd even or no configurable parity - communication protocol: Modbus on terminaltype of polarization No impedance - communication protocol: Modbusnumber of addresses 1...127 - communication protocol: CANopen1...247 - communication protocol: Modbusmethod of access Slave - communication protocol: CANopenfunction available Safe standstill for power circuitPTC relay for power circuitPt100 relay for power circuitInsulation monitoring for power circuitDesign for IT networks for power circuitExternal 230 V supply terminals for power circuitBuffer voltage 24 V DC power supply for power circuitEnclosure lighting for power circuitKey switch (local/remote) for power circuitMotor heating for power circuitExternal motor fan for power circuitVoltmeter for power circuitDoor handle for main switch for power circuitAmmeter for power circuitEnclosure heating for power circuitMotor choke for power circuitCable entry via the top for power circuitEnclosure plinth for power circuitRelay output C/O for control circuitExternal 24 V DC supply terminals for power circuitControl terminals for control circuitAdaptor for 115 V logic inputs for control circuitIsolated amplifier for control circuitoption card Communication card - communication protocol: CC-LinkCommunication card - communication protocol: DeviceNetCommunication card - communication protocol: Ethernet/IPCommunication card - communication protocol: FipioCommunication card - communication protocol: Interbus-SCommunication card - communication protocol: Modbus PlusCommunication card - communication protocol: Modbus TCPCommunication card - communication protocol: Modbus/Uni-TelwayCommunication card - communication protocol: Profibus DPCommunication card - communication protocol: Profibus DP V1Controller inside programmable cardBasic I/O extension cardExtended I/O extension cardEncoder interface cardsoperating position Vertical +/- 10 degreecolour of enclosure Light grey RAL 7035width 800 mmheight 2157 mmdepth 642 mmproduct weight 605 kgEnvironment IP degree of protection IP23standards EN 60204-1EN 61800-3 environments 2 category C3EN 61800-5-1EN 61800-2product certifications ATEXC-TickGOSTmarking CEnoise level 69 dBpollution degree 2 conforming to EN/IEC 61800-5-1vibration resistance 0.6 gn (f=10...200 Hz) conforming to EN/IEC 60068-2-61.5 mm peak to peak (f=3...10 Hz) conforming to EN/IEC 60068-2-63M3 conforming to EN/IEC 60721-3-3shock resistance 4 gn 11 ms conforming to EN/IEC 60068-2-273M2 conforming to EN/IEC 60721-3-3environmental characteristic 3K3 without condensation conforming to IEC 60721-3-3relative humidity 0...95 %ambient air temperature for operation 0...40 °C without derating40...50 °C with current derating of 1.8 % per °Cambient air temperature for storage -25...70 °Cvolume of cooling air 1200 m3/hoperating altitude <= 1000 m without derating1000...3000 m with current derating 1 % per 100 m -
Documents and Downloads
Language- English
- Russian
- French
CatalogueSizeAdd to My DocumentsCatalog: Altivar 71/71 Plus variable speed drives - English version 2014/04 (web pdf format) (Version 1.0)Date 8/10/18Size 10.7 MBCatalogue : variateurs de vitesse Altivar 71/71 Plus - Version française 2014/04 (format PDF web) (Version 1.0)Date 8/10/18Size 14.3 MBCertificateSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions -
Connections and Schema
Wiring DiagramA1DriveA2EnclosureAICActive Infeed ConverterMMotorQ1Main switch built-in as standardQ2Optional circuit breakerF1Main fusesKM1Line contactorEMCEMC filterLFCLine Filter Choke(1)Control(2)Relay control(3)Reference potentiometer(4)Option motor choke -
Performance Curves
Derating CurvesThe derating curves for the drive nominal current (In) are dependent on the temperature and switching frequency. For intermediate temperatures, interpolate between 2 curves.
NOTE: The drive will reduce the switching frequency automatically in the event of excessive temperature rise.
XSwitching frequency (kHz)NOTE: The temperatures shown correspond to the temperature of the air entering the enclosure.