Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Schneider Electric ATV312HU11M3412 Image

Range: Altivar 312 Solar

Variable speed drives

ATV312HU11M3412

Schneider Electric ATV312HU11M3412 Image
Range: Altivar 312 Solar

Variable speed drives

ATV312HU11M3412

variable speed drive ATV312 - 1.1kW - 3kVA - 71 W - 200..240 V - 3-phase supply

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Altivar 312 Solar
    product or component type
    Variable speed drive
    product destination
    Asynchronous motors
    product specific application
    Pumping station with photovoltaic arrays
    assembly style
    With heat sink
    device short name
    ATV312
    Complementary
    motor power kW
    1.1 kW
    motor power hp
    1.5 hp
    [Us] rated supply voltage
    200...240 V (- 5...5 %)
    supply voltage limits
    170...264 V
    supply frequency
    50...60 Hz (- 5...5 %)
    network frequency
    47.5...63 Hz
    network number of phases
    3 phases
    line current
    7.4 A at 240 V
    8.5 A at 200 V, Isc = 1 kA
    EMC filter
    Without EMC filter
    apparent power
    3 kVA
    prospective line Isc
    1 kA
    continuous output current
    6.9 A at 4 kHz
    maximum transient current
    10.4 A for 60 s
    power dissipation in W
    71 W at nominal load
    speed drive output frequency
    0.5...500 Hz
    nominal switching frequency
    4 kHz
    switching frequency
    2...16 kHz (adjustable)
    speed range
    1...50
    transient overtorque
    150...170 % of nominal motor torque
    braking torque
    <= 150 % with braking resistor for 60 s
    100 % with braking resistor continuously
    150 % without braking resistor
    asynchronous motor control profile
    Factory set: energy saving mode
    regulation loop
    Frequency PI regulator
    motor slip compensation
    Adjustable
    Automatic whatever the load
    Suppressable
    output voltage
    <= power supply voltage
    electrical connection
    Terminal - cable cross section: 2.5 mm², AWG 14 (terminal(s) Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6)
    Terminal - cable cross section: 2.5 mm², AWG 14 (terminal(s) L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-)
    tightening torque
    0.6 N.m (terminal(s) Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6)
    0.8 N.m (terminal(s) L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-)
    insulation
    Electrical between power and control
    supply
    Internal supply for logic inputs at 19...30 V, <= 100 A, protection type: overload and short-circuit protection
    Internal supply for reference potentiometer (2.2 to 10 kOhm) at 10...10.8 V, <= 10 A, protection type: overload and short-circuit protection
    analogue input number
    3
    analogue input type
    AI1 configurable voltage 0...10 V, 30 V max, impedance: 30000 Ohm
    AI2 configurable voltage +/- 10 V, 30 V max, impedance: 30000 Ohm
    AI3 configurable current 0...20 mA, impedance: 250 Ohm
    sampling duration
    8 ms (terminal(s) AI1, AI2, AI3), input: analog
    4 ms (terminal(s) LI1...LI6), input: discrete
    response time
    8 ms, output: analog (terminal(s) AOV, AOC)
    8 ms, output: discrete (terminal(s) R1A, R1B, R1C, R2A, R2B)
    linearity error
    +/- 0.2 % output
    analogue output number
    2
    analogue output type
    AOC configurable current 0...20 mA, impedance: 800 Ohm, resolution: 8 bits
    AOV configurable voltage 0...10 V, impedance: 470 Ohm, resolution: 8 bits
    discrete input logic
    LI1...LI4 logic input not wired, < 13 V (state 1)
    LI1...LI6 negative logic (source), > 19 V (state 0)
    LI1...LI6 positive logic (source), < 5 V (state 0), > 11 V (state 1)
    discrete output number
    2
    discrete output type
    R1A, R1B, R1C configurable relay logic, 1 NO + 1 NC, electrical service life: 100000 cycles
    R2A, R2B configurable relay logic, NC, electrical service life: 100000 cycles
    minimum switching current
    10 mA at 5 V DC (terminal(s) R1-R2)
    maximum switching current
    2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)
    2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)
    5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)
    5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)
    discrete input number
    6
    discrete input type
    LI1...LI6 programmable at 24 V, 0...100 mA for PLC, impedance: 3500 Ohm
    acceleration and deceleration ramps
    Linear adjustable separately from 0.1 to 999.9 s
    S, U or customized
    braking to standstill
    By DC injection
    protection type
    Line supply overvoltage and undervoltage safety circuits for drive
    Line supply phase loss safety function, for three phases supply for drive
    Motor phase breaks for drive
    Overcurrent between output phases and earth (on power up only) for drive
    Overheating protection for drive
    Short-circuit between motor phases for drive
    Thermal protection for motor
    Input phase breaks for drive
    dielectric strength
    2040 V DC between earth and power terminals
    2880 V AC between control and power terminals
    insulation resistance
    >= 500 mOhm at 500 V DC for 1 minute
    local signalling
    1 LED (red) signal for drive voltage
    Four 7-segment display units signal for CANopen bus status
    time constant
    5 ms for reference change
    frequency resolution
    0.1...100 Hz for analog input
    0.1 Hz for display unit
    communication port protocol
    Modbus
    CANopen
    connector type
    1 RJ45 for Modbus/CANopen
    physical interface
    RS485 multidrop serial link
    transmission frame
    RTU
    transmission rate
    10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen
    4800, 9600 or 19200 bps for Modbus
    number of addresses
    1...247 for Modbus
    1...127 for CANopen
    number of drive
    127 for CANopen
    31 for Modbus
    electromagnetic compatibility
    1.2/50 µs - 8/20 µs surge immunity test - test level 3 conforming to IEC 61000-4-5
    Electrical fast transient/burst immunity test - test level 4 conforming to IEC 61000-4-4
    Electrostatic discharge immunity test - test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test - test level 3 conforming to IEC 61000-4-3
    standards
    IEC 61800-5-1
    IEC 61800-3
    marking
    CE
    height
    329.5 mm
    width
    245 mm
    depth
    192 mm
    product weight
    1.7 kg
    option card
    Communication card for CANopen daisy chain
    Communication card for Profibus DP
    Communication card for Modbus TCP
    Communication card for Fipio
    Communication card for DeviceNet
    Environment
    IP degree of protection
    IP20 without cover plate
    pollution degree
    2
    protective treatment
    TC
    vibration resistance
    1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
    1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
    shock resistance
    15 gn for 11 ms conforming to EN/IEC 60068-2-27
    relative humidity
    5...95 % without condensation conforming to IEC 60068-2-3
    5...95 % without dripping water conforming to IEC 60068-2-3
    ambient air temperature for storage
    -25...70 °C
    ambient air temperature for operation
    -10...50 °C without derating with protective cover on top of the drive
    -10...60 °C with derating factor without protective cover on top of the drive
    operating altitude
    <= 1000 m without derating
    >= 1000 m with current derating 1 % per 100 m
    operating position
    Vertical +/- 10 degree
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Russian
    • French
    User guide
    Date
    Size
    Add to My Documents
    Date 1/4/17
    Size 6 MB
    Certificate
    Date
    Size
    Add to My Documents
    Date 7/18/18
    Size 1.7 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.