product composition |
EnclosurePhase-shifting transformerMedium voltage arrestorsCooling fansHuman machine interfacePlinth (2)Power cells (24)
|
|
EMC filter |
Integrated
|
|
network number of phases |
3 phases
|
|
input type |
48 pulse diode rectifier bridge
|
|
output type |
Transistor (IGBT)
|
|
[Us] rated supply voltage |
10 kV (tolerance:+/- 10 %)
|
|
supply voltage limits |
2970...3630 V
|
|
supply frequency |
50/60 Hz (tolerance:+/- 5 %)
|
|
[Uc] control circuit voltage |
220 V
|
|
motor power kW |
2341 kW
|
|
line current |
200 A
|
|
drive efficiency with transformer (including fan power) |
>= 96 % (standard efficiency)
|
|
total losses at 100 % load including fan power |
<= 94 kW (standard efficiency)
|
|
apparent power |
2800 kVA
|
|
prospective line Isc |
31.5 kA for 150 ms
|
|
overload withstand |
1.5 In for 3 s (standard overload)1.85 In for 3 s (high overload)1.2 In for 60 s (standard overload)1.5 In for 60 s (high overload)
|
|
continuous output current |
162 A (standard overload)129 A (high overload)
|
|
maximum transient current |
194 A for 60 s
|
|
speed drive output frequency |
0.5...70 Hz (vector control with/without speed feedback)0.5...120 Hz (voltage/frequency ratio (V/f))
|
|
nominal switching frequency |
600 Hz
|
|
speed range |
20...100
|
|
asynchronous motor control profile |
Sensorless flux vector controlVoltage/frequency ratio (V/f)Vector control with sensor, optionalClosed-loop control with encoder
|
|
synchronous motor control profile |
Voltage/frequency ratio (V/f)Closed-loop control with encoder
|
|
overvoltage category |
II conforming to EN/IEC 61800-5-1
|
|
display type |
LCD display for operation function, status and configuration
|
|
output voltage |
<= power supply voltage
|
|
isolation |
Electrical between power and control
|
|
electrical connection |
Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top
|
|
supply |
Internal supply for cooling fan at 380 V ACExternal supply for cooling fan at 380 V AC (optional)External supply for control at 220 V AC, 3 kVAExternal supply for control at 220 V AC/DC (optional)
|
|
analogue input number |
4
|
|
analogue input type |
Software-configurable current, 0...20 mA/4...20 mA, 24 V max, input impedance: 250 Ohm
|
|
analogue output number |
24 (optional)
|
|
analogue output type |
Software-configurable voltage, 0...10 V DCSoftware-configurable current, 0...20 mA/4...20 mA DC, output impedance: 250 Ohm
|
|
discrete output number |
14 (optional)10
|
|
discrete input number |
10 (optional)6
|
|
acceleration and deceleration ramps |
Linear from 0...3200 s
|
|
protection type |
Overcurrent for driveOvervoltage for driveUndervoltage for driveController shutdown for driveCooling fan stop for driveOverload for driveOver temperature protection for driveCommunication failure for drivePhase loss for driveGround fault protection for drive
|
|
dielectric strength |
28 kV AC between earth and power terminals
|
|
frequency resolution |
0.01 Hz for output
|
|
communication port protocol |
1 DeviceNet (SUB-D 9) human machine interface1 Modbus TCP (RJ45) human machine interface1 Profibus (SUB-D 9) human machine interface1 Modbus (SUB-D 9), RS485, 2-wire human machine interface1 Ethernet IP (RJ45) human machine interface
|
|
operating position |
Vertical +/- 10 degree
|
|
colour of enclosure |
Grey (RAL 7032)
|
|
width |
6870 mm (standard efficiency)
|
|
depth |
1500 mm (standard efficiency)
|
|
height |
2670 mm (standard efficiency)
|
|
product weight |
9100 kg (standard efficiency)
|
|