Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

    Schneider Electric ATS01N222QN Image

    Range: Motor Starter Components Finder

    Products for Motor protection and control

    ATS01N222QN

    Schneider Electric ATS01N222QN Image
    Range: Motor Starter Components Finder

    Products for Motor protection and control

    ATS01N222QN

    soft starter for asynchronous motor - ATS01 - 22 A - 380..415V - 7.5..11 KW

    Show more characteristics >
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      Altistart 01
      product or component type
      Soft starter
      product destination
      Asynchronous motors
      product specific application
      Simple machine
      device short name
      ATS01
      network number of phases
      3 phases
      [Us] rated supply voltage
      380...415 V - 10...10 %
      motor power kW
      11 kW 3 phases 380...415 V
      7.5 kW 3 phases 380...415 V
      IcL starter rating
      22 A
      utilisation category
      AC-53B EN/IEC 60947-4-2
      current consumption
      110 A at nominal load
      type of start
      Start with voltage ramp
      power dissipation in W
      124.5 W in transient state
      4.5 W at full load and at end of starting
      Complementary
      assembly style
      With heat sink
      function available
      Integrated bypass
      supply voltage limits
      342...456 V
      supply frequency
      50...60 Hz - 5...5 %
      network frequency
      47.5...63 Hz
      output voltage
      <= power supply voltage
      [Uc] control circuit voltage
      Built into the starter
      starting time
      1 s 100
      10 s 10
      5 s 20
      Adjustable from 1 to 10 s
      deceleration time symb
      Adjustable from 1 to 10 s
      starting torque
      30...80 % of starting torque of motor connected directly on the line supply
      discrete input type
      Logic LI1, LI2, BOOST stop, run and boost on start-up functions <= 8 mA 27 kOhm
      discrete input voltage
      24...40 V
      discrete input logic
      Positive LI1, LI2, BOOST < 5 V and <= 0.2 mA > 13 V >= 0.5 mA
      discrete output current
      2 A DC-13
      3 A AC-15
      discrete output type
      Open collector logic LO1 end of starting signal
      Relay outputs R1A, R1C NO
      discrete output voltage
      24 V 6...30 V open collector logic
      minimum switching current
      10 mA 6 V DC relay outputs
      maximum switching current
      2 A 250 V AC inductive cos phi = 0.5 20 ms relay outputs
      2 A 30 V DC inductive cos phi = 0.5 20 ms relay outputs
      display type
      1 LED green starter powered up
      1 LED yellow nominal voltage reached
      tightening torque
      0.5 N.m
      1.9...2.5 N.m
      electrical connection
      4 mm screw clamp terminal rigid 1 1...10 mm² AWG 8 power circuit
      Screw connector rigid 1 0.5...2.5 mm² AWG 14 control circuit
      4 mm screw clamp terminal rigid 2 1...6 mm² AWG 10 power circuit
      Screw connector rigid 2 0.5...1 mm² AWG 17 control circuit
      Screw connector flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit
      4 mm screw clamp terminal flexible without cable end 1 1.5...10 mm² AWG 8 power circuit
      Screw connector flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit
      4 mm screw clamp terminal flexible with cable end 2 1...6 mm² AWG 10 power circuit
      4 mm screw clamp terminal flexible without cable end 2 1.5...6 mm² AWG 10 power circuit
      Screw connector flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
      marking
      CE
      operating position
      Vertical +/- 10 degree
      height
      154 mm
      width
      45 mm
      depth
      131 mm
      product weight
      0.56 kg
      compatibility code
      ATS01N2
      power range
      7...11 kW at 380...440 V 3 phases
      motor starter type
      Soft starter
      Environment
      electromagnetic compatibility
      Damped oscillating waves level 3 IEC 61000-4-12
      Electrostatic discharge level 3 IEC 61000-4-2
      Immunity to electrical transients level 4 IEC 61000-4-4
      Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
      Voltage/current impulse level 3 IEC 61000-4-5
      Conducted and radiated emissions level B CISPR 11
      Conducted and radiated emissions level B IEC 60947-4-2
      EMC immunity EN 50082-2
      Harmonics IEC 1000-3-2
      Harmonics IEC 1000-3-4
      Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6
      Micro-cuts and voltage fluctuation IEC 61000-4-11
      EMC immunity EN 50082-1
      standards
      EN/IEC 60947-4-2
      product certifications
      B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
      CCC
      CSA
      C-Tick
      GOST
      UL
      IP degree of protection
      IP20
      pollution degree
      2 EN/IEC 60947-4-2
      vibration resistance
      1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6
      1 gn 13...150 Hz EN/IEC 60068-2-6
      shock resistance
      15 gn 11 ms EN/IEC 60068-2-27
      relative humidity
      5...95 % without condensation or dripping water EN/IEC 60068-2-3
      ambient air temperature for operation
      -10...40 °C without derating
      40...50 °C with current derating of 2 % per °C
      ambient air temperature for storage
      -25...70 °C EN/IEC 60947-4-2
      operating altitude
      <= 1000 m without derating
      > 1000 m with current derating of 2.2 % per additional 100 m
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      • Russian
      • French
      Catalogue
      Date
      Size
      Add to My Documents
      Date 2/2/17
      Size 2 MB
      Date 2/2/17
      Size 2.1 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 6/19/18
      Size 65.4 KB
      Date 6/19/18
      Size 179.8 KB
      Date 4/27/18
      Size 360.8 KB
      Date 5/31/18
      Size 25.6 KB
      Date 6/22/18
      Size 469.4 KB
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 12/13/17
      Size 120.2 KB
      End of life manual
      Date
      Size
      Add to My Documents
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.