  • Main
    range of product
    Acti 9
    product name
    Acti 9 Smartlink
    product or component type
    Smart communication module
    device short name
    Smartlink SI B Ethernet
    Application type
    Load control
    Breaker status monitoring
    Basic energy metering E
    Improved load monitoring E, U, I, P, Pf
    Number max of connected devices
    Up to 7 wired devices
    group of channels
    1 group of 7 digital channels
    1 group of 1 analog channel
    maximum supply current
    1.5 A
    [Us] rated supply voltage
    24 V DC +/- 20 %
    connectivity to devices
    Analog input
    Digital input and output
    Pulse output meter
    communication service
    Ethernet Modbus TCP/IP server
    Web server
    web server
    BMS controller compatible
    Embedded web page
    web services
    Web page
    Complementary
    application specific I/O
    Pulse totalising counter
    Pulse converter
    protection type
    Short-circuit protection for analogue input
    Against reverse polarity for auxiliary supply
    Against reverse polarity for input
    Overvoltage at 33 V DC for digital output
    immunity to microbreaks
    10 ms
    reset
    Factory reset on front face
    input/output type
    2 inputs + 1 output per digital channel
    2 inputs per analog channel
    input type
    Current for analog input, 4...20 mA
    Voltage for analog input, 0...10 V DC
    Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA
    maximum permanent current
    0.005 A for digital input
    absolute accuracy error
    +/- 1 % of full scale for analog input 12 bits
    electronic filtering time
    2 ms for digital input from state 0 to state 1
    2 ms for analog input from state 0 to state 1
    output type
    Logic current source: 24 V - DC - 100 mA
    maximum voltage drop
    <1 V at state 1 digital output
    inrush current
    0.5 A for digital output
    3 A for power supply
    local signalling
    Communication: 1 LED (yellow)
    NS (Network Status): 1 LED (green, orange and red)
    Communication (LK/ACT 10/100): 1 LED (green and yellow)
    Status: 1 LED (green, orange and red)
    type of setting
    Modbus address 01...247 for address encoders
    mounting position
    Horizontal and vertical on DIN rail
    colour
    White (RAL 9003)
    location of connection
    Front
    connections - terminals
    Spring-loaded terminal Ti24 qty: 7 for digital input/output, ordered separately
    RJ45 connector qty: 1 for ETHERNET, ordered separately
    Plug-in connector qty: 1 for supply circuit
    Plug-in connector qty: 1 for communication bus
    Plug-in connector qty: 1 for analog input
    clamping connection capacity
    2 x 0.25 mm² for twisted shielded pairs cable, flexible with cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, flexible without cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, rigid with cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, rigid without cable end for communication bus
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for analog input
    1 x 0.5...1 x 1.5 mm², flexible with cable end for control
    1 x 0.5...1 x 1.5 mm², flexible without cable end for control
    1 x 0.5...1 x 1.5 mm², rigid with cable end for control
    1 x 0.5...1 x 1.5 mm², rigid without cable end for control
    2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit
    wire stripping length
    Control: 10 mm
    Supply circuit: 7 mm
    Analog input: 7 mm
    Communication bus: 7 mm
    communication network type
    RS485 Modbus RTU master SUB-D 9 9.6...19.2 kbauds
    Ethernet Modbus TCP/IP server RJ45 10/100 Mbit/s
    9 mm pitches
    0 useful
    height
    22.5 mm
    width
    359 mm
    depth
    42 mm
    net weight
    180 g
    provided equipment
    Set of 1 connector
    Set of 1 bus connector
    Set of 1 power supply connector
    Set of 2 locking clips
    range compatibility
    iTL auxiliary
    RCA iC60 Ti24 connector
    Linergy FM
    iOF+SD 24
    iACT24
    iATL24
    pulse output meter
    Modbus meter
    Acti 9 iCT auxiliary
    Acti 9 iC60
    Acti 9 iID
    Acti 9 iSW-NA
    Acti 9 iDPN Vigi
    Acti 9 C40
    Multi 9 C60
    Acti 9 DT40
    Acti 9 DT60
    Acti 9 I-NA
    Acti 9 ITG40
    Acti 9 iDPN
    Acti 9 Reflex iC60 Ti24 connector
    commissioning interface
    Acti 9 Smart test
    Web page
    compatibility code
    Acti 9 Smartlink IP
    Environment
    IP degree of protection
    IP20
    pollution degree
    3
    electromagnetic compatibility
    Resistance to electrostatic discharge (air discharge), 8 kV, conforming to IEC 61000-4-2
    Resistance to electrostatic discharge (contact discharge), 4 kV, conforming to IEC 61000-4-2
    Resistance to radiated electromagnetic fields (80 MHz...3 GHz), 10 V/m, conforming to IEC 61000-4-3
    Power supply: resistance to fast transient (5...100 kHz), 2 kV, conforming to IEC 61000-4-4
    Input/output: resistance to fast transient, 1 kV, conforming to IEC 61000-4-4
    Communication bus: resistance to fast transient, 1 kV, conforming to IEC 61000-4-4
    Conducted EMC (0.15...80 MHz), 10 V, conforming to IEC 61000-4-6
    Immunity to magnetic fields at network frequency, 30 A/m, conforming to IEC 61000-4-8
    Radiated emission (30...1000 MHz), class A, conforming to IEC 61131-3 Ed.3
    Conducted emission (0.15...30 MHz), class A, conforming to IEC 61131-2
    environmental characteristic
    Corrosive 3C2 conforming to IEC 60721-3-3
    Salt mist 2 conforming to IEC 60068-2-52
    vibration resistance
    1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to IEC 60068-2-6
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    fire resistance
    Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10
    On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10
    tropicalisation
    2
    relative humidity
    93 % at 40 °C
    operating altitude
    0...2000 m
    ambient air temperature for operation
    -25…60 °C
    ambient air temperature for storage
    -40…80 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Documents

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • Chinese
    • German
    • Dutch
    User guide
    Date
    Size
    Add to My Documents
    Sistema di comunicazione Acti 9 Smartlink Ethernet - Manuale utente (Version 03)
    Kommunikationssystem Acti 9 Smartlink Ethernet - Benutzerhandbuch (Version 03)
    Acti9 Smartlink SI B - Manuel d'utilisation (Version 03)
    Acti9 Smartlink SI B Benutzerhandbuch (Version 03)
    Acti9 Smartlink SI B Manual del usuario (Version 03)
    Acti9 Smartlink SI B Manuale utente (Version 03)
    Acti 9 Système de communication Smartlink Ethernet - Manuel d’utilisation (Version 03)
    Sistema de comunicación Acti 9 Smartlink Ethernet - Manual del usuario (Version 03)
    Acti9 Smartlink SI B – User Manual (Version 03)
    Sistema de Comunicação Acti 9 Smartlink Ethernet Manual de Utilizador (Version 03)
    Acti 9 Smartlink Ethernet Communication System - User Manual (Version 03)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for A9XMEA08: Acti9 Smartlink - Modbus TCP/IP communication I/O module (Version 2.0)
    Smart Panels - typical architecture for small buildings (Version 1.0)
    Smart Panels - typical architecture for medium-size buildings (Version 1.0)
    Acti 9 Smartlink Ethernet - CAD model (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    Acti 9 Smartlink Ethernet (A9XMEA08) - Acti 9 Smartlink SI B (A9XMZA08) - Installation instruction (Version 05)
    Catalogue page
    Date
    Size
    Add to My Documents
    Acti9 Smartlink (Version 2.0)
    Date 6/4/15
    Size 2.5 MB
    Acti 9 Smartlink (Version 2.0)
    Date 6/4/15
    Size 2.5 MB
    End of Life Information
    Date
    Size
    Add to My Documents
    Acti 9 Control IP - EoLi (Version 1.0)
    Date 5/22/14
    Size 113.5 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /