ARA auto recloser aux for iC60 1P-1PN-2P - 4 Prog

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Acti 9
    product or component type
    Automatic recloser auxiliary
    device short name
    ARA iC60
    signal contacts composition
    2 OF volt-free contacts
    signalling circuit voltage
    24 V 10 mA AC/DC
    230 V 1 A AC
    Complementary
    control type
    Inhibition of automatism maintained 230 V AC 50/60 Hz
    Ultimate reclosing impulse 230 V AC 50/60 Hz
    input current
    5 mA
    impulse duration
    >= 200 ms control circuit
    response time
    < 500 ms
    [Us] rated supply voltage
    230 V AC 50/60 Hz
    power consumption in W
    2 W
    [Ui] rated insulation voltage
    400 V
    [Uimp] rated impulse withstand voltage
    6 kV
    value of setting
    Program 1 : 1 reclosing attemp, short cycle <= 10 s before reclosing / 6 min check time
    Program 2 : 3 reclosing attemps, short cycle <= 10 s before reclosing / 2 min check time
    Program 2 : 3 reclosing attemps, short cycle <= 1 min before reclosing / 6 min check time
    Program 2 : 3 reclosing attemps, short cycle <= 3 min before reclosing / 6 min check time
    Program 3 : 5 reclosing attemps, long fixed cycle <= 10 s before reclosing / 2 min check time
    Program 3 : 5 reclosing attemps, long fixed cycle <= 1 min before reclosing / 6 min check time
    Program 3 : 5 reclosing attemps, long fixed cycle <= 3 min before reclosing / 6 min check time
    Program 4 : 5 reclosing attemps, long progressive cycle <= 10 s before reclosing / 2 min check time
    Program 4 : 5 reclosing attemps, long progressive cycle <= 1 min before reclosing / 6 min check time
    Program 4 : 5 reclosing attemps, long progressive cycle <= 3 min before reclosing / 8 min check time
    Program 4 : 5 reclosing attemps, long progressive cycle <= 4 min before reclosing / 10 min check time
    Program 4 : 5 reclosing attemps, long progressive cycle <= 5 min before reclosing / 12 min check time
    local signalling
    Flashing orange LED : not operational
    Flashing green LED : normal operation
    Flashing red LED : reclosing cycle in progress
    Fixed red LED : automatic recloser locked
    mounting mode
    Clip-on
    mounting support
    DIN rail
    comb busbar and distribution block compatibility
    NO
    9 mm pitches
    7
    height
    93 mm
    width
    63 mm
    depth
    75.5 mm
    product weight
    440 g
    colour
    White
    electrical durability
    5000 cycles
    provision for padlocking
    Padlockable
    wire stripping length
    Power supply : 10 mm (bottom)
    Input : 10 mm (bottom)
    Output : 8 mm (top)
    tightening torque
    Power supply : 1 N.m
    Input : 1 N.m
    Output : 0.7 N.m
    range compatibility
    Acti 9: Acti 9 iC60
    product compatibility
    IC60 2P
    IC60 1P + N
    IC60 1P
    Environment
    IP degree of protection
    IP20 conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60947
    overvoltage category
    II
    tropicalisation
    2
    relative humidity
    93 % at 40 °C
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -25...60 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    User guide
    Date
    Size
    Add to My Documents
    Dispositivo automatico di richiusura ARA - Interruttori iC60 - Manuale di riferimento (Version 03)
    ARA Automatic Recloser - iC60 Circuit Breakers - Reference Manual (Version 03)
    Automatismo de religação ARA - Disjuntores iC60 - Manual de referência (Version 03)
    Rückstellungsautomat ARA - Leistungsschalter iC60 - Referenzhandbuch (Version 03)
    Automatismo de reenganche ARA - Interruptores automáticos iC60 - Manual de referencia (Version 03)
    Automatisme de ré-enclenchement ARA - Disjoncteurs iC60 - Manuel de Référence (Version 03)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for A9C70132: ARA auto recloser aux for iC60 1P-1PN-2P - 4 Prog (Version 2.0)
    ARA Automatic Recloser Auxiliary for iC60 1-2P
    Instruction sheet
    Date
    Size
    Add to My Documents
    ARA iC60 - Acti 9 automatic reclosers for iC60 circuit breakers (Version 03)
    End of Life Information
    Date
    Size
    Add to My Documents
    Acti 9 ARA - Automatic Recloser Auxiliary (Version 1.1)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 5/3/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Acti 9 ARA - Automatic Recloser Auxiliary (Version 1.1)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 5/3/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.