The maximum number of products that can be compared is 4

  • Main
    range
    Multi 9
    product or component type
    Voltage release
    device short name
    CNV
    poles description
    2P
    Complementary
    [Ue] rated operational voltage
    230 V AC 50 Hz between phase and neutral
    supply voltage limits
    50…440 V AC, 1 phase
    [Ie] rated operational current
    40 A
    OV/UV auto-reset complusive delay time
    Overvoltage: 275 V (Tripping time:3…15 s)
    Overvoltage: 300 V (Tripping time:1…5 s)
    Overvoltage: 350 V (Tripping time:0.25…0.75 s)
    Overvoltage: 400 V (Tripping time:0.1…0.2 s)
    Undervoltage: 50...160 V (Tripping time:0.6…5 s)
    Lockout:
    reset
    Automatic reset 25…35 s 253 V for overvoltage
    Automatic reset 25…35 s 195 V for undervoltage
    Electric clearance
    1.2 mm
    maximum leakage current
    2 mA
    creepage distance
    5.6 mm
    [Uimp] rated impulse withstand voltage
    4 kV between phases
    4 kV between phase and neutral
    local signalling
    Indicator light green, steady for fault
    Indicator light green, flashing for lock
    Indicator light red, steady for operating
    time delay
    0...800 s on-delay
    function available
    Real time voltage detection
    [Ui] rated insulation voltage
    500 V
    rated breaking and making capacity
    320 A 242 V, cos phi = 0.85 (12 times)
    [Icw] rated short-time withstand current
    504 kA during 4 s
    mounting support
    DIN rail
    mounting mode
    By clips
    cable entry
    Bottom entry
    mounting location
    Downstream
    installation direction
    Horizontal
    Vertical
    Use category
    Indoor installation
    9 mm pitches
    4
    height
    84.8 mm
    width
    36 mm
    depth
    72 mm
    colour tint
    Clips: light grey (RAL 7035)
    Housing: light grey (RAL 7035)
    electrical durability
    12000 cycles at 63 A 285 V AC cos phi 0.9
    mechanical robustness
    Vibrations (3 Gn, 5…100 Hz) conforming to IEC 60068-2-6
    Shocks 6 ms with protective package (30 Gn) conforming to IEC 60068-2-27
    Free fall resistance 0.8m, without package
    service life
    10 year(s)
    electromagnetic compatibility
    Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
    Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
    Surge immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5
    Surge immunity test - test level: 4 kV (differential mode) conforming to IEC 61000-4-5
    Electrical fast transient/burst immunity test - test level: 4 kV, 2.5 kHz, 5 kHz and 100 kHz conforming to IEC 61000-4-4
    Immunity to conducted disturbances - test level: 10 V, 0.15...80 MHz level 3 conforming to IEC 61000-4-6
    Immunity to conducted RF disturbances - test level: 10 V, 80...1000 MHz and 1400...6000 MHz level 3 conforming to IEC 61000-4-3
    Conducted emission class B
    Radiated emission class B
    connections - terminals
    Tunnel type terminals top or bottom1…35 mm² rigid without cable end
    Tunnel type terminals top or bottom1…25 mm² flexible with or without cable end
    tightening torque
    Power circuit: 3.5 N.m
    Environment
    standards
    JB/T 12762-2015
    product certifications
    REACH
    directives
    2002/95/EC - RoHS directive
    IP degree of protection
    IP40 on front face conforming to IEC 60529
    IP20 B other parts conforming to IEC 60529
    pollution degree
    2
    operating altitude
    <= 2000 m
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -40…80 °C
    relative humidity
    0…75 % operating
    0…95 % storage
    Offer Sustainability
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
  • View more View less

    Documents

    Language
    • English4
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 146.8 KB
    Date 6/30/16
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    Multi 9 OV/UV + auto reset release - 2P - 40A
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /