  • Main
    range of product
    Sepam series 20
    Sepam series 60
    Sepam series 80
    Sepam series 80 NPP
    Sepam series 40
    Sepam series 48
    device short name
    ACE949-2
    Complementary
    communication port protocol
    Modbus RTU network: E-LAN interface: RS485 - 2-wire
    Modbus RTU network: S-LAN interface: RS485 - 2-wire
    local signalling
    LED for link activity on front face
    [Us] rated supply voltage
    12 V DC tolerance: +/- 10 %
    24 V DC tolerance: +/- 10 %
    supply current
    <= 16 mA : receiving mode
    <= 40 mA : maximum in sending mode
    mounting mode
    Fixed
    mounting support
    Symmetrical DIN rail
    height
    88 mm
    width
    72 mm
    depth
    30 mm
    product weight
    0.1 kg
    mechanical robustness
    Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
    Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
    Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
    Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
    Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
    Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
    cable distance between devices
    10 Devices <= 180 m cable length at 12 V DC
    10 Devices <= 750 m cable length at 24 V DC
    20 Devices <= 160 m cable length at 12 V DC
    20 Devices <= 450 m cable length at 24 V DC
    25 Devices <= 125 m cable length at 12 V DC
    25 Devices <= 375 m cable length at 24 V DC
    5 Devices <= 1000 m cable length at 24 V DC
    5 Devices <= 320 m cable length at 12 V DC
    auxiliary connection terminal
    Earthing terminal : screw-type connector cable 2.5...50 mm² <= 0.2 m
    Earthing terminal : screw-type connector tinned copper braid 6...100 mm²
    tightening torque
    Earthing terminal : 2.2 N.m
    Environment
    electromagnetic compatibility
    Fast transient bursts immunity tests-conducted disturbances : IV (4kV, 2.5 kHz ) conforming to IEC 61000-4-4
    Immunity to radiated fields immunity tests-radiated disturbances : III (10 V/m, 80 MHz...2 GHz ) conforming to IEC 61000-4-3
    Disturbing field emission emission tests : A conforming to EN 55022
    Fast transient bursts immunity tests-conducted disturbances : A and B (4kV, 2.5 kHz/2 kV, 5 kHz ) conforming to IEC 60255-22-4
    Immunity to conducted RF disturbances immunity tests-conducted disturbances : III (10 V ) conforming to IEC 60255-22-6
    Conducted disturbance emission emission tests : A conforming to EN 55022
    Immunity to magnetic fields at network frequency immunity tests-radiated disturbances : IV (30 A/m (continuous)-300 A/m (1-3 s) ) conforming to IEC 61000-4-8
    Surges immunity tests-conducted disturbances : III (2 kV CM, 1 kV DM ) conforming to IEC 61000-4-5
    1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM ) conforming to IEC 60255-22-1
    1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV DM ) conforming to ANSI C37.90.1
    100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM ) conforming to IEC 61000-4-12
    Conducted disturbance emission emission tests conforming to IEC 60255-25
    Disturbing field emission emission tests conforming to IEC 60255-25
    Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to ANSI C37.90.3
    Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to IEC 60255-22-2
    Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI C37.90.1
    Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz ) conforming to IEC 60255-22-3
    Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz ) conforming to ANSI C37.90.2
    Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to IEC 60255-11
    climatic withstand
    Continuous exposure to damp heat (in operation) : Cab : 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Cab : 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Db : 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30
    Exposure to cold (in operation) : Ad : - 25 °C conforming to IEC 60068-2-1
    Exposure to cold (in storage) : Ab : - 25 °C conforming to IEC 60068-2-1
    Exposure to dry heat (in operation) : Bd : 70 °C conforming to IEC 60068-2-2
    Exposure to dry heat (in storage) : Bb : 70 °C conforming to IEC 60068-2-2
    Salt mist (in operation) : Kb/2 : 6 days conforming to IEC 60068-2-52
    Temperature variation with specified variation rate (in storage) : Nb : - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14
    Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
    Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
    ambient air temperature for operation
    -25...70 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0926  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
    Available
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Catalogue Sepam serie 20, 40, 60, 80 - Cover (Version 6.0)
    User guide
    Date
    Size
    Add to My Documents
    Sepam série 80, manuel d'exploitation (Version 10)
    Sepam série 20, manuel d'utilisation (Version 9)
    Sepam series 20, user's manual (Version 9)
    Sepam, guide d'aide à l'installation (Version 0)
    CAD
    Date
    Size
    Add to My Documents
    ACE949-2 (Version 1.0)
    Date 1/13/05
    Size 39.1 KB
    Date 1/13/05
    Size 47.4 KB
    Date 1/13/05
    Size 2.8 KB
    Date 1/13/05
    Size 6.1 KB
    Connecting ACE949-2 (Version 1.0)
    Date 1/13/05
    Size 31.7 KB
    Date 1/13/05
    Size 27.1 KB
    Date 1/13/05
    Size 1.4 KB
    Date 1/13/05
    Size 3.3 KB
    ACE949-2 (Version 1.0)
    Date 1/13/05
    Size 38.9 KB
    Date 1/13/05
    Size 46.8 KB
    Date 1/13/05
    Size 2.7 KB
    Date 1/13/05
    Size 5.1 KB
    ACE949-2 (Version 1.0)
    Date 1/13/05
    Size 34.4 KB
    Date 1/13/05
    Size 35 KB
    Date 1/13/05
    Size 1.7 KB
    Date 1/13/05
    Size 3.4 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 9/17/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP Sepam series 80 [2003-2004 format] (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 9/17/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /