Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

interface and automatic controller - ACP + UA with communication - 220..240 V

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Compact NS630b...1600
    NSX100...250
    Masterpact NW
    Masterpact NT
    Compact NS100...630
    NSX400...630
    product or component type
    Interface and control unit
    accessory / separate part category
    Interlocking accessory
    range compatibility
    Compact - Compact NS circuit breaker
    Compact - Compact NSX circuit breaker
    Masterpact - Masterpact NT circuit breaker
    Masterpact - Masterpact NW circuit breaker
    device short name
    ACP + UA 150
    [Us] rated supply voltage
    220...240 V AC 50/60 Hz
    Complementary
    operating mode
    Stop (both normal and replacement source off)
    Automatic operation
    Forced operation on replacement source
    Forced operation on normal source
    interlocked device
    NSX400...630
    Compact NS630b...1600
    Masterpact NT
    NSX100...250
    Masterpact NW
    Compact NS100...630
    selection modes
    Circuit breaker on R
    Circuit breaker on N
    test function
    By pressing the test button on the front of the controller
    complementary function
    Additional contact: transfer to replacement source only if contact is closed
    Selection of type of normal source (single-phase or three-phase)
    Setting of maximum startup time for the replacement source
    Voluntary transfer to replacement source (e.g. energy management commands)
    Forced normal source if replacement source not operational during peak-tariff
    local signalling
    Fault trip
    Off
    On
    input type
    Contacts customer voluntary order to transfer to source R
    output type
    Contacts customer : indication of operation in automatic or stop mode
    [Ith] conventional free air thermal current
    8 A
    [Ie] rated operational current
    DC-12 : 2 A DC 48 V
    AC-12 : 4 A AC 440 V
    AC-12 : 5 A AC 380/415 V
    AC-12 : 8 A AC 110 V
    AC-12 : 8 A AC 220/240 V
    AC-12 : 8 A AC 24 V
    AC-12 : 8 A AC 48 V
    AC-13 : 6 A AC 110 V
    AC-13 : 6 A AC 220/240 V
    AC-13 : 7 A AC 24 V
    AC-13 : 7 A AC 48 V
    AC-14 : 4 A AC 110 V
    AC-14 : 4 A AC 220/240 V
    AC-14 : 5 A AC 24 V
    AC-14 : 5 A AC 48 V
    AC-15 : 3 A AC 220/240 V
    AC-15 : 4 A AC 110 V
    AC-15 : 5 A AC 24 V
    AC-15 : 5 A AC 48 V
    DC-12 : 0.4 A DC 250 V
    DC-12 : 0.6 A DC 110 V
    DC-12 : 8 A DC 24 V
    DC-13 : 2 A 24 V
    product compatibility
    Compact NSX400...630
    Compact NSX100...250
    Compact NS630b...1600
    Environment
    standards
    IEC 947-5-1
    IP degree of protection
    Connectors : IP20 conforming to EN 60529
    Front : IP40 conforming to EN 60529
    Side : IP30 conforming to EN 60529
    IK degree of protection
    Front : IK07 conforming to EN 50102
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    catalog source changeover system- Compact NS/NSX/INS-INV/Masterpact (Version 2.1)
    Catalogue page
    Date
    Size
    Add to My Documents
    Références/PowerLogic System (Version 3.0)
    Date 12/18/06
    Size 765.8 KB
    Inverseur de source Compact NS100 à NS630 et C801 à C1251 (Version 4.0)
    Substitution document
    Date
    Size
    Add to My Documents
    Guide de substitution Compact NSX100 à 630 (Version 1.1)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /