Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Vigirex
Schneider Electric 28563 Image

28563

Schneider Electric 28563 Image
28563

Monitoring relay Vigirex RMH - 30 mA..30 A - 220..240 V AC

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    Vigirex
    range of product
    Vigirex
    device short name
    RMH
    product or component type
    Monitoring relay
    range compatibility
    Vigirex Vigirex RMH L rectangular sensor
    Vigirex Vigirex RMH RM12T multiplexer
    Vigirex Vigirex RMH TOA earth leakage current sensor
    Vigirex Vigirex RMH A earth leakage current sensor
    relay application
    Current control relay
    Monitoring relay
    Complementary
    earthing system
    TN-S
    TT
    [Us] rated supply voltage
    220...240 V AC at 400 Hz 70...110 %
    220...240 V AC at 50/60 Hz 70...110 %
    power consumption in VA
    8 VA
    type of measurement
    Earth fault current internal measurement 80...100 % +/- 10 %
    threshold setting
    0.015...1 A adjustable in step of 0.001 A pre-alarm
    1...30 A adjustable in step of 0.1 A pre-alarm
    0.03...1 A adjustable in step of 0.001 A alarm
    1...30 A adjustable in step of 0.1 A alarm
    residual earth-leakage time delay adjustment type
    Adjustable 0.03...30 A 0...5 s
    type of setting
    Keypad
    Internal bus
    signal contacts composition
    1 NO
    test function
    Local
    monitoring
    Electronics (continuous)
    Power supply (continuous)
    Relay/sensor link (continuous)
    Sensor/multiplexer RM12T and RM12T/RMH link (continuous)
    [Ithe] conventional enclosed thermal current
    8 A
    minimum load
    10 mA at 12 V
    product weight
    0.3 kg
    IP degree of protection
    IP40 front face conforming to IEC 60529
    IP30 other parts conforming to IEC 60529
    IP20 connection conforming to IEC 60529
    IK degree of protection
    IK07 conforming to EN 50102
    mechanical robustness
    Vibrations 13.2...100 Hz : 0.7 g
    Vibrations 2...13.2 Hz : +/- 1 mm
    Fire resistance conforming to IEC 60695-2-1
    earth-leakage protection class
    Class AC
    Class A si
    overvoltage category
    IV
    tamperproof of settings
    Protected by sealable cover
    mounting support
    Panel
    height
    72 mm
    width
    72 mm
    depth
    116 mm
    connections - terminals
    Terminal block alarm circuit 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block alarm circuit 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block alarm circuit 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    Terminal block auxiliary power supply 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block auxiliary power supply 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block auxiliary power supply 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    Terminal block communication bus 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block communication bus 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block communication bus 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    Terminal block multiplexer connection 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block multiplexer connection 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block multiplexer connection 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    Terminal block pre alarm 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block pre alarm 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block pre alarm 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    Terminal block voltage presence 0.2...2.5 mm² flexible AWG 22...AWG 12
    Terminal block voltage presence 0.2...2.5 mm² rigid AWG 22...AWG 12
    Terminal block voltage presence 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12
    wire stripping length
    Auxiliary power supply : 6 mm
    Alarm circuit : 6 mm
    Communication bus : 6 mm
    Voltage presence : 6 mm
    Multiplexer connection : 6 mm
    Pre alarm : 6 mm
    tightening torque
    Alarm circuit : 0.5 N.m
    Auxiliary power supply : 0.5 N.m
    Voltage presence : 0.5 N.m
    Communication bus : 0.5 N.m
    Multiplexer connection : 0.5 N.m
    Pre alarm : 0.5 N.m
    communication service
    Supervision via internal bus
    Environment
    ambient air temperature for operation
    -25...55 °C
    ambient air temperature for storage
    -40...85 °C
    electromagnetic compatibility
    Conducted and radiated emissions : B conforming to CISPR 11
    Conducted radio-frequency immunity test : 3 conforming to IEC 61000-4-6
    Electrostatic discharge immunity test : 4 conforming to IEC 61000-4-2
    High-energy conducted susceptibility : 4 conforming to IEC 61000-4-5
    Low-energy conducted susceptibility : 4 conforming to IEC 61000-4-4
    Radiated susceptibility : 3 conforming to IEC 61000-4-3
    electrical shock protection class
    Class II
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    VIGIREX RMH 220/240VAC (Version 1.0)
    Date 9/11/13
    Size 368.3 KB
    Date 9/11/13
    Size 351.9 KB
    Electrical schematics RMH (Version 1.0)
    Date 2/3/05
    Size 39.4 KB
    Date 2/3/05
    Size 87.8 KB
    Date 2/3/05
    Size 4.2 KB
    Date 2/3/05
    Size 123.4 KB
    Mechanical drawings\Overall dimensions\3D view (Version 1.0)
    Mechanical drawings\Overall dimensions\Front view (Version 1.0)
    Mechanical drawings\Overall dimensions\Facial view (Version 1.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP Vigirex RH10P to RH99P with associated sensors (Version 1.1)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /