Title
Using Connexium Configurator utility to setup Connexium switch IP address 
 
Issue
Procedure for setting up the initial IP address or change an existing IP address on a Connexium managed switch
 
Product Line
Connexium Managed switches
 

Resolution
 First, Open up the Connexium Configurator utility and select the Local Ethernet interface IP address used on your PC to connect to the Connexium Switch
1. Click Down Arrowhead to display the available IP addresses
2. Click the IP address to Select

After the IP address of PC is selected.
1. Click the Rescan button to scan for Connexium switches on the network

The IP address of the discovered Connexium Switches are displayed
1. Select the number 1 entry to assign a new IP address
2. Then select Edit from the tool bar
3. Select 'Change Device Properties' from menu 
4. Type in new IP address, Subnet Mask and Default Gateway for the Connexium Switch
5. Click 'Save as Default' button to setp new IP address as default IP
6. Click Okay button
7. The new IP address has been assigned to the Connexium Switch

To Change the IP address of a Connexium Switch that already has an IP address
1. Select the appropriate row that has the Connexium switch you want to change IP address 
2. Then select Edit from the tool bar
3. Select 'Change Device Properties' from menu 
4. Type in new IP address, Subnet Mask and Default Gateway for the Connexium Switch
5. Type in new IP address, Subnet Mask and Default Gateway for the Connexium Switch
6. Click 'Save as Default' button to setp new IP address as default IP
7. Click Okay button
8. The changed IP address has been assigned to the Connexium Switch 

Now that the new IP addresses have been assigned to the Connexium Switches, the Configuration utility can be closed.
 