Question
How to configure the 4G interface on a HMIBSC Edge Box ?

Description



~# vi ~/infra_settings.conf
  Set W4G_SETTINGS_FLAG=1
  Set W4G_SIM_PIN="<PIN_CODE>"
  Set W4G_APN="<APN_NAME>"
  Set W4G_USERNAME="<xxxxxx>" # If needed
  Set W4G_PASSWORD="<xxxxxx>" # If needed
Save file: press 'Esc key', enter :wq then press 'Enter key'
~# reboot
~# ~/utility/w4g/w4g_setup.sh
~# ping <8.8.8.8>  # Google DNS

Keywords
HMIBSC, BSC, Edge Box, Magelis Ipc, 4G, configuration, HMIYMIN4GUS1, HMIYMIN4GEU1, network, interface