How to fix problem when TSXCUSB485 or TSXCUSB232 cable is not recognized by windows 10?

Published date: 08 January 2019

Goals and Symptoms
Does Windows 10 doesn't recognize the connection cable TSXCUSB485 or TSXCUSB232

Facts and Change
TSXCUSB485, TSXCUSB232

Causes and Fixes

Be sure you have administrator rights. The most probable reason is that windows provides the driver from windows update site instead of using the driver from SchneiderModbusDriverSuite (part of Unity Pro/ControExpert installation).
  1. In Device manager, uninstall TSX cable driver (in Serial USB folder) when TSXCUSB485/TSXCUSB232 cable is plugged in.
  2. Run "Device installation setting" and select "install driver software from windows update only if not found on PC"
  3. Uninstall Driver Manager x64. (search DriverManager x64 in registry HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Uninstall, then copy the uninstall string (msexec...) and run it
  4. Unplug the TSX cable, restart PC
  5. Run "Turn windows features on or off" and check if microsoft  .NET framework is enabled including 2 sub options (Foundation HTTP activation, Framework activation)
  6. Install the driver (schneiderModbusDriverSuite 14_12 or newer) or re-install Unity Pro completely. 
  7. Plug in TSX cable and check in device manager if the cable appears in com port folder. If so, problem is solved.