What are the Vijeo Designer v6.2 Runtime specifications/limitations?

Published date: 28 January 2019

Issue:
What are the Vijeo Designer v6.2 Runtime specifications/limitations?

Product Line:
Vijeo Designer, XBTGC/GK/GT, HMIGK/GTO/GTU/STO/STU, iPC, Panel PC, Box PC

Resolution:
Below are the Runtime specifications for Vijeo Designer v6.2.

Run-Time Specifications

  • Use the following statistics as only a guideline for creating your own applications. Some applications may not be able to run despite remaining below these documented numbers because of memory limitations. To make sure your application will run correctly, check the memory requirement for each panel and operation, and compare these requirements with your target machine. For details, see Section 25.3.3, Checking Memory Usage. Always test your application thoroughly before running it in a production environment.
  • The following statistics were obtained by testing each individually on factory machines. These numbers will vary depending on the operating environment, the complexity of the application, the CPU load, and the amount of memory available on the target machine. Some of these performance numbers can be enhanced with upgraded memory, CF Cards/SD Cards, and hard disks.
Panels
Number of panels/popup windows (limit) The number of panels that can be created in a project depends on the amount of flash memory available on your target machine and on the size of  each panel. For example, you can have a project on an XBTGT6330 target that contains 100 panels.
As the number of panels for your project increases, memory consumption also increases.
Number of objects on a panel (recommended) The number of objects that can be placed on a panel depends on the target machine's panel height and width. For example, you can have a project on an XBTGT6330 target that contains 200 objects per panel.
As the number of objects placed on a panel increases, memory consumption also increases.
Popup windows (limit) Number of popup windows that can be displayed at run time: maximum of 3, which includes the popup keypad.
Large Toolchest parts On some targets, large parts placed on a panel may cause a wait time to occur when changing panels. For example, on an XBTGC 2230U, switching from one panel to another panel with a Web Browser took several seconds.
Actions
Maximum number of actions 100
Scripts
Maximum length of each script (recommended)
For other script recommendations, see Section 18.3.4, Key Points.
50 lines
Error Logging
Number of run-time events stored 100
Alarms and Events
Number of Alarm Groups and Event Groups in a Target (limit) 32 max.
Number of Alarm Categories and Remote Categories in a Target (limit) 32 max.
Number of event records in an event group (limit) The number of event records you can store in each event group is 10,000 max. Events are recorded in both History and Log, which results in having two event records for each event that occurs. For example, if you set 10,000 as the maximum number of total records, you can only store 5000 events.
Number of alarms in alarm groups (limit) The number of Log and History alarm records you can store in each alarm group is 10,000 max.
In the Alarms node, when Backup Alarm Group is set to No, you can store up to 80,000 total Log and History alarms in a target's alarm groups.
When Backup Alarm Group is Yes, the number of alarms is limited by the space available on SRAM.
Number of alarms in an alarm category (limit) and remote category 60,000
Alarm Backup
The size required by each alarm message depends on the alarm type.
Active: 20 bytes per record
History: 24 bytes per record
Log: 16 bytes per record
SRAM Capacity (Backup) is different for each target machine type.
128 to 512 KB (Depends on model. Refer to your hardware manual.)
For information about how much SRAM is required by your project, see Section 4.5.1, Target Properties.
E-mail
Number of attachments per e-mail 1 max.
Maximum size of file attachment 10 MB
Link Objects
Maximum number of definition objects (per Target node) 100
Maximum of folder levels in the folder structure for definition objects (per Target node) 5
Files
Number of text files (limit) 200 max.
Text file size (recommended) 50KB max.
Number of video files (limit) 200 max.
Number of sound files (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
1,500 200 200
Languages
Number of user languages you can create (allowed) 15 max.
Variables
Number of variables per panel (limit) HMIG5U / HMIG5U2 / iPC Series All other target types
Maximum 2500 variables per panel Maximum 800 variables per panel.
Number of variables per target (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
12000 max. 8000 max. 8000 max.
  • For iPCs, if persistent variables such as alarm variables and data logging variables are used, a maximum of 8000 variables can be supported for each iPC target.
Number of variables you can share (recommended) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
400 300 300
  • The Maximum Number of Shared Variables is the recommended maximum number of variables that is shared at any one time NOT the maximum number of Sharing-enabled (Read-only or Read/Write) variables. In other words, the number of variables that you set to Read-Only or Read/Write has no limits; only the number of variables that are accessed by other targets is limited. Performance may become an issue if you exceed the recommended maximum.
Security
Number of security groups per target 20 max.
Number of users per security group 100 max.
Number of users per target 100 max.
Number of users per Vijeo Designer project 200 max.
Driver Restrictions on Windows Target Machines
Biometric Switch The Biometric Switch's USB driver currently does not support Windows target machines running on embedded Windows operating systems, including Windows XP Embedded and Windows Embedded 7.
Drivers not supported on target machines that run Windows operating systems The following drivers are not supported on Windows operating systems, and therefore Windows target machines cannot connect to physical equipment using these drivers. Simulation in Buildtime is also not supported.
Schneider Electric:
  • Modbus TCP/IP USB
  • Modbus Plus
  • Modbus Slave RTU
  • FIPIO
  • FIPWAY
Siemens AG:
  • MPI/PPI
Rockwell Automation:
  • DH485
Data Logging
Number of Data Logging Groups in a target (limit) 80
Maximum number of variables being logged in a target HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGT1005 / XBTGT2000 and higher / XBTGC / XBTGK / HMIGTO / HMISCU / HMIGK Series HMISTO / HMISTU Series XBTGH Series
250 variables max. 100 variables max. 60 variables max. 80 variables max.
Table Resources
Maximum number of table resources in a tablet/smartphone project 10
Maximum number of states in a table resource 255
Resource Library
Maximum number of Text, Color, Image, Font Resources in a project (limit) 256
Maximum size of an image file used in an image resource 1920x1080
Forms Printing
Number of forms you can create for each user application (limit) 50 max.
Maximum number of objects on one form (recommended) 2000
Communication
Number of equipment nodes (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
80 max. 48 max. 48 max.
Number of scan groups per equipment (limit) 20 max. per equipment node
Number of Maximum Share Connections (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTU / HMIGK / HMISCU Series XBTGK Series
32 8 8
  • The maximum number of shared connections includes:
  • Remote targets in target-to-target sharing
  • Web Gate
  • Vijeo Design'Air Plus mobile devices
  • Remote alarm access from other targets
  • Intelligent Data Services (IDS) tool access
Recipe
Total number of recipe groups (standard recipe group or Parison Recipe Group) per target 32 max.
Number of recipes in a recipe group (limit) 256 max.
Number of ingredients in each recipe (limit) for a standard recipe group 1024 max.
Number of ingredients in each recipe (limit) for a Parison Recipe Group 64 min.
400 max.
 
The user application you create in the Editor is restricted by target machine run-time specifications. The following table lists the memory capacity of available target machines. DRAM memory affects how much information you can display on the panel at one time. Internal Memory affects the total size of your application. SRAM memory affects how much information you can store between run-time sessions.
If you are using a tablet/smartphone, the memory capacity depends on the model. See the manufacturer's specifications for more information.
 
Target Machine Memory (DRAM) Storage Media / Internal Memory (Flash Memory) Memory (SRAM)
Magelis iPC Compact MPC KT52 256 or 512 MB N.A. 2 MB (Simulated)
Compact MPC KT22 512 or 1024 MB N.A. 2 MB (Simulated)
Compact MPC KT12 512 or 1024 MB N.A. 512 KB
Compact MPC KT55xx2 512, 1024, or 2048 MB N.A. 512 KB
Compact MPC KT22xxx20 512 MB N.A. 512 KB
Compact PC Box MPC KN02 512 MB N.A. 512 KB
Smart MPC ST52 256, 512, or 1024 MB N.A. 2 MB (Simulated)
Smart MPC ST21 256, 512, or 1024 MB N.A. 2 MB (Simulated)
Smart MPC ST11 256 or 512 MB N.A. 512 KB
Smart/Smart+ MPC ST52xx2/HMI PSx7 256, 512, or 1024 MB N.A. 512 KB
Smart Box MPC SN01 256 MB N.A. 512 KB
Smart MPC ST21xxx20 512 MB N.A. 512 KB
Flex PC Box PTX MPC02 512 MB N.A. 2 MB (Simulated)
Flex PC Box PTX MPC05 512 MB N.A. 2 MB (Simulated)
Box Performance HMIBPxxx2 2-8 GB Storage media 512 KB
Box Performance HMIBPxxx5 2-8 GB Storage media 512 KB
Box Universal HMIBUxxx1 1-3 GB Storage media 512 KB
Box Universal HMIBUxxx2 1-3 GB Storage media 512 KB
HMIGTW5354/Panel W HMIPWC5 1-2 GB Storage media 512 KB
HMIGTW7354x/Panel Optimum HMI PWC7/PVC7 1-2 GB Storage media 512 KB
Panel Performance HMIPPx6 4 GB DDR3 (in 1 slot) Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
Panel Performance HMI PPx7/PRx7 2-8 GB Storage media 512 KB
Panel Performance HMIPPx9 2-8 GB Storage media 512 KB
Panel Universal HMIPUx6 2 GB DDR3 (in 1 slot) Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
Panel Universal HMI PUx7/PTx7 1-3 GB Storage media 512 KB
Panel Universal HMIPUx9 1-3 GB Storage media 512 KB
XBTGTW450 512 MB N.A. 2 MB (Simulated)
XBTGTW652 256, 512, or 1024 MB N.A. 2 MB (Simulated)
XBTGTW750/HMIGTW7353 512 MB N.A. 2 MB (Simulated)
Rack PC Optimized HMIRSO/HMIRXO 2 GB Storage media Use Internal Flash to simulate SRAM.
Rack PC Universal HMIRSU 4 GB Storage media Use Internal Flash to simulate SRAM.
Rack PC Performance HMIRSP 4 GB Storage media Use Internal Flash to simulate SRAM.
S-BOX PC Optimized HMIBSO 2 GB Storage media Use Internal Flash to simulate SRAM.
S-BOX PC Universal HMIBSU 4 GB Storage media Use Internal Flash to simulate SRAM.
S-Panel Performance HMIPSPx7 8 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
S-Panel Performance HMIPSPx9 8 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
Enclosed PC Performance HMIPEPx9 8 GB Storage media 2 MB (Simulated)
S-Panel Optimized HMIPSOx5 4 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
S-Panel Optimized HMIPSOx7 4 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
Box Universal HMIBMU 4 GB Storage media 512 KB
Performance HMIBMP 8 GB Storage media 512 KB
Magelis HMIGTO Series HMIGTO1300 128 MB 64 MB 128 KB
HMIGTO1310 128 MB 96 MB 512 KB
HMIGTO2300 128 MB 64 MB 128 KB
HMIGTO2310 128 MB 96 MB 512 KB
HMIGTO2315 128 MB 96 MB 512 KB
HMIGTO3510 128 MB 96 MB 128 KB
HMIGTO4310 128 MB 96 MB 512 KB
HMIGTO5310 128 MB 96 MB 512 KB
HMIGTO5315 128 MB 96 MB 512 KB
HMIGTO6310 128 MB 96 MB 512 KB
HMIGTO6315 128 MB 96 MB 512 KB
Magelis HMIGTU Series HMIG3U 256 MB 1 GB 512 KB
HMIG5U 2 GB 16 GB 512 KB
HMIG5U2 2 GB 16 GB 512 KB
Magelis HMISCU Series HMISAC (HMIS65/S85) 128 MB 128 MB 128 KB
HMISBC (HMIS65/S85) 128 MB 128 MB 128 KB
Magelis HMISTO Series HMISTO501 32 MB 16 MB 128 KB (Simulated)
HMISTO511 32 MB 16 MB 128 KB (Simulated)
HMISTO512 32 MB 16 MB 128 KB (Simulated)
HMISTO531 32 MB 16 MB 128 KB (Simulated)
HMISTO532 32 MB 16 MB 128 KB (Simulated)
Magelis HMISTU Series HMISTU655 32 MB 16 MB 64 KB
HMISTU855 32 MB 16 MB 64 KB
HMIS5T 64 MB 32 MB 64 KB
Magelis XBTGT Series XBTGT7340 64 MB 32 MB 512 KB
XBTGT6340 64 MB 32 MB 512 KB
XBTGT6330 32 MB 32 MB 512 KB
XBTGT5430 32 or 64 MB*1 32 MB 512 KB
XBTGT5340 64 MB 32 MB 512 KB
XBTGT5330 32 MB 32 MB 512 KB
XBTGT5230 32 MB 32 MB 512 KB
XBTGT4340 64 MB 32 MB 512 KB
XBTGT4330 32 MB 32 MB 512 KB
XBTGT4230 32 MB 32 MB 512 KB
XBTGT2930 64 MB 16 MB 512 KB
XBTGT2430 64 MB 32 MB 512 KB
XBTGT2330 32 MB 16 MB 512 KB
XBTGT2220 32 MB 16 MB 512 KB
XBTGT2130 32 MB 16 MB 512 KB
XBTGT2120 32 MB 16 MB 512 KB
XBTGT2110 32 MB 16 MB 128 KB
XBTGT1335 32 MB 32 MB 128 KB
XBTGT1135 32 MB 32 MB 128 KB
XBTGT1105 32 MB 32 MB 128 KB
Magelis XBTGC Series XBTGC1100T 32 MB 16 MB 512 KB
XBTGC1100U 32 MB 16 MB 512 KB
XBTGC2120T 32 MB 16 MB 512 KB
XBTGC2120U 32 MB 16 MB 512 KB
XBTGC2230T 32 MB 16 MB 512 KB
XBTGC2230U 32 MB 16 MB 512 KB
XBTGC2330T 32 MB 16 MB 512 KB
XBTGC2330U 32 MB 16 MB 512 KB
Magelis XBTGH Series XBTGH2460 64 MB 32 MB 512 KB
Magelis XBTGK Series XBTGK2120 32 MB 16 MB 512 KB
XBTGK2330 32 MB 16 MB 512 KB
XBTGK5330 32 MB 32 MB 512 KB
Magelis HMIGK Series HMIGK2310 128 MB 96 MB 512 KB
HMIGK5310 128 MB 96 MB 512 KB
 
*1 The XBTGT5430 model comes in two versions that differ in their DRAM size (32 MB or 64 MB). To determine the version of the XBTGT5430, look for the following serial numbers on the manufacturer's label on your target machine:  
  • 32 MB: PV: 01, RL: 00, SV: 1.0
  • 64 MB: PV: 01, RL: 01, SV: 1.1
In Vijeo Designer when you select XBTGT5430 as a target machine, by default it is set to the 64 MB version. No additional memory check is performed for the 32 MB version. Make sure your application does not exceed the amount of DRAM available on your target machine. To find out the amount of memory available on a target machine, see Section 26.4.6, Displaying Memory.
 