Check PME 8.x web application's CPU and Memory usage

Issue
The memory usage of web application components is needed to troubleshoot high memory use or to optimize performance

Product Line
Power Monitoring Expert PME 8.x , SPM 7.0.x

Resolution
Internet Information Services (IIS) Manager contains a feature called Worker Processes that can be used to monitor the memory and CPU usage on the server.

1- Make sure that PME's Web Applications is already open in any supported browser.
2- Navigate to IIS manager and click on the server name.
3- Double-click on Worker Processes as shown in the picture below.

4- The worker processes will list all the Application pools in use. 

Private Memory (Committed bytes) corresponds to actual RAM usage