For SSR relay, which EMC-relevant parts of the EN 61000 standard are met, in particular, is it part 1 + 3?

NO, there is no EMC declaration on our EU DOC certificate. See attached file, EU DOC - 2016  SSP3 SSM1 SSM2 SSL1 SSLZ.pdf.
 
Here is the reason, refer to IEC62314:2006 standard.
 
Solid state relays are components (not stand alone devices) and as such do not perform a
direct function. Therefore, no EMC requirements are included in this standard.
 
NOTE This is in line with the European EMC Directive.