What is the minimum speed of rotation for Lexium Integrated Drives of the ILE type (Brushless DC motors)

Published date: 20 November 2018

The minimum speed for ILE1x devices is 300 rpm's, while the minimum speed for ILE2x devices is 60 rpm's
This is because the newer design ILE2x types have improved signal evaluation of the internal position feedback.

Speeds lower then the minimum are possible but the motion will be non-continuous motions. (stepping rotation)

It should be noted that ILE devices only have 12 encoder points per rotation, therefore speed regulation is not very good. 
ILE devices are designed and intended for use for format applications.


rev 11-20-18