Is it possible to install Vijeo Designer as a silent install?

Published date: 28 March 2019

Issue:
Is it possible to install Vijeo Designer as a silent install?

Product Line:
Vijeo Designer

Environment:


Cause:


Resolution:
Yes, you can install Vijeo Designer as a silent install.  Below are the parameters that could be used for the install:
 
 
Type Description Notes
FIRSTNAME:
String User's first name  
LASTNAME:
String User's last name  
COMPANYNAME
String User's company name  
REFERENCENUM
String Product Reference number If empty string, then the installer will use a pre-defined reference number
SERIALNUM
String Product Serial number If empty string, then the installer will use a pre-defined serial number
INSTALLDIR
String Installation path of Vijeo Designer If empty string, then the installer will use a pre-defined destination path
PROJECTSPATH
String Installation path of Vijeo Designer Projects If empty string, then the installer will use a pre-defined projects path
STARTMENUPATH
String Start Menu folder location If empty string, then the installer will use a pre-defined start menu folder path
DESKTOPSC
Boolean Specifies to create a desktop shortcut If the value is “true”, create a desktop shortcut. If “false”, do not create desktop shortcut
QUICKLAUNCHSC
Boolean Specifies to create a quicklaunch shortcut If the value is “true”, create a quick launch shortcut. If “false”, do not create a quick launch shortcut
INSTALLALLLANGS
Boolean Specifies to install all application languages When false, only the English language and help files are installed. If true, install all application languages and help files.
DEFAULTLANG
String Specifies default application language If empty string, then use language of locale. Possible values are ENU, CHS, DEU, FRA, ITA, ESP
ADMINRIGHTS
Boolean Specifies to install as Administrator If “false”, install Vijeo Designer with for User Rights. If “true” installer Vijeo Designer for Administrator Rights
DEMO
Boolean Specifies to install in Demo mode If “true”, install Vijeo Designer in Demo mode. If “false”, install Vijeo Designer in Standard Mode.
 


































 
Below is an example on how the parameters above are used:
msiexec /i "C:\InstallerDirectory\Vijeo Designer 6.2.msi" FIRSTNAME="User" LASTNAME="User" COMPANYNAME="INDE Electronics" REFERENCENUM="VJDSNDTGSV62M" SERIALNUM="01234567890" INSTALLDIR="C:\Program Files\Schneider Electric\Vijeo Designer" DESKTOPSC="true" QUICKLAUNCHSC="true" ADMINRIGHTS="true" INSTALLALLLANGS="false" DEFAULTLANG="ENU" /qb

Where 62 in the REFERENCENUM="VJDSNDTGSV62M" signifies the version of Vijeo Designer you are installing.