Technical FAQs

Ask a Question

What IIS Components are required for SPM/PME installation?

Customer wants to know what components are required to be installed prior to performing SPM/PME installation, and they also want to verify that all components were installed correctly during the process.

Product Line
Struxureware Power Monitoring 7.0 or higher
Power Monitoring Expert 7.2 or higher

Web Applications 

Uninstalling, or missing components would cause some segments of the Web Application not to function properly.


The following sections need to be installed prior to starting the SPM/PME installation:

i) Common HTTP Features
  •  Static Content
  •  Default Document
  •  Directory Browsing
  •  HTTP Errors
ii) Health and Diagnostics
  •  HTTP Logging
  •  Request Monitor
iii) Security
  • Request Filtering
iv) Performance Features
  •  Static Content Compression
v) Management Tools
  •  IIS Management Console

e) In addition the followings are installed:
i) Application Development Features
  • (1) ASP.NET
  •  .NET Extensibility
  • (3) ASP
  • (a) If prompted to add other role services, required by selections, click “Add Required Role Services”.
  • (4) ISAPI Extensions
  • (5) ISAPI Filters
  • ii) Management Tools
(1) IIS 6 Management Compatibility
  •  IIS 6 Metabase and IIS configuration compatibility
  •  IIS 6 WMI Compatibility
  •  IIS 6 Scripting Tools 
Was this helpful?
What can we do to improve the information ?