Technical FAQs

Ask a Question

What could cause the Magelis to get a blue screen with the following error message: "Application Has Halted.. Memory allocation failed.. KAOScore:NonPortableMisc.cpp : line 709"

Issue:
What could cause the Magelis to get a blue screen with the following error message: "Application Has Halted..  Memory allocation failed..  KAOScore:NonPortableMisc.cpp : line 709"



Product Line:
Magelis XBTGH/GK/GT, HMIGTO/STO/STU, iPC

Environment:


Cause:


Resolution:
You could get the following error if the Magelis is running out of DRAM.  This usually happens in a Magelis that is part of the Somachine project.  We recommend only move Somachine variables into the Symbols Configurator that are to be used in the Magelis.  As Somachine variables uses up a lot memory.  Or the other recommendation is to go with a Magelis screen that has more DRAM, preferably a HMIGTO series.
Was this helpful?
What can we do to improve the information ?