How to adjust the request packet interval (RPI) on an Ethernet IP slave.

Goals and Symptoms

How to adjust the request packet interval (RPI) on an Ethernet IP slave.

Facts and Changes

TSXETC100, 140NOC771100

Causes and Fixes

The request packet interval (RPI) for an Ethernet IP slave device is configurable using the following
steps.

  • Double click on the 'Ethernet/IP' icon to open the Ethernet IP Configuration Tool,
  • Double click on the slave device to open the slave properties configuration window.
  • Click on 'Connections'.
  • Click on 'General'
  • Double click on 'Request Packet Interval'.
  • Change the value in the textbox in the 'Setting' section of the winodw.
  • Click 'OK'.
  • Click 'OK' to close the slave properties configuration window.
  • Click on 'Save' to save the changes.