Technical FAQs

Ask a Question

'Performance Counter is disabled' message gets returned when starting the Advantys Configuration Software

Goals and Symptoms

'Performance Counter is disabled' message gets returned when starting of the Advantys Configuration Software

Facts and Changes

All versions of Advantys Configuration Software

Causes and Fixes


The reason why the error is being returned is due to one of the services that the Advantys
Configuration Software requires, does not have the performance counters enabled. It is a
Microsoft Windows registry related issue..

Performance counters are part of the Microsoft Windows operating system. They are used to provide
information as to how well the operating system or an application, service, or driver is performing.
The counter data is used to help determine bottlenecks in the operating system. It is also used for
fine-tuning the operating system and application performance. The performance counter are
pre-defined during the installation of the operating system and it's services. (This requires full
administrative access to the registry.) The installation or updates of the software components with
Microsft patches, hot fixes could include new additional services and performance counters.
Newer services or updates of the registry could also accompany the installation of any software.

Ususally on a 64 bit Windows XP operating system, all the performance counters are disabled by
default. If you are trying to run the software on a 64 bit Windows XP operating system, the error would
be returned.(The Advantys Configuration Software is not supported on a 64 bit Windows operating
system.)

Anything (i.e., firewall settings, not logged in as an administrator, etc.) blocking the access to the registry
could prevent the performance counters from being properly configured in the registry.

In a manner that is similiar to all software developed for Windows by any third party, the 'Advantys
Configuration Software' uses a lot of standard pre-installed Microsoft components. Since these
components rely on specific services within the operating system, it is very difficult to determine
which service the error is related to.

To resolve the issue, the user can try:

  • Uninstalling the software.
  • Cleaning the regisrty.
  • Re-installing the 'Advantys Configuration Software'.

Note: User must be logged in as an administrator before installing the software.

Legacy KB System (APS) Data: RESL192838 V1.0, Originally authored by AlCh on 10/02/2008, Last Edited by AlCh on 10/02/2008
Related ranges: Advantys STB
Was this helpful?
What can we do to improve the information ?