• Default Alternative Text

    Traditional Data Center

    Solutions for data centers greater than 1 MW capacity.

    • Read

      • Read more about Schneider Electric solutions

        White Paper #150
        Power and Cooling Capacity Management for Data Centers

        High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management. Read White Paper #150
      • Read more about Schneider Electric solutions

        White Paper #107
        How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Costs

        Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery. Read White Paper #107
      • Read more about Schneider Electric solutions

        White Paper #165
        Types of Prefabricated Modular Data Centers

        Data center systems or subsystems that are pre-assembled in a factory are often described with terms like prefabricated, containerized, modular, skid-based, pod-based, mobile, portable, self-contained, all-in-one, and more. There are, however, important distinctions between the various types of factory-built building blocks on the market. This paper proposes standard terminology for categorizing the types of prefabricated modular data centers, defines and compares their key attributes, and provides a framework for choosing the best approach(es) based on business requirements. Read White Paper #165
      • Read more about Schneider Electric solutions

        White Paper #166
        Practical Considerations for Implementing Prefabricated Data Centers

        Implementing prefabricated modular data centers results in well-understood benefits including speed of deployment, predictability, scalability, and lifecycle cost. The process of deploying them – from designing the data center, to preparing the site, to procuring the equipment, to installation – is quite different than that of a traditional data center. This paper presents practical considerations, guidance, and results that a data center manager should expect from such a deployment. Read White Paper #166
      • Read more about Schneider Electric solutions

        White Paper #114
        Implementing Energy Efficient Data Centers

        Electricity usage costs have become an increasing fraction of the total cost of ownership (TCO) for data centers. It is possible to dramatically reduce the electrical consumption of typical data centers through appropriate design of the network-critical physical infrastructure and through the design of the IT architecture. This paper explains how to quantify the electricity savings and provides examples of methods that can greatly reduce electrical power consumption. Read White Paper #114
      • Read more about Schneider Electric solutions

        White Paper #147
        Data Center Projects: Advantages of Using a Reference Design

        It is no longer practical or cost-effective to completely engineer all aspects of a unique data center. Re-use of proven, documented subsystems or complete designs is a best practice for both new data centers and for upgrades to existing data centers. Adopting a well-conceived reference design can have a positive impact on both the project itself, as well as on the operation of the data center over its lifetime. Reference designs simplify and shorten the planning and implementation process and reduce downtime risks once up and running. In this paper reference designs are defined and their benefits are explained. Read White Paper #147
      • Read more about Schneider Electric solutions

        White Paper #195
        Fundamentals of Managing the Data Center Life Cycle for Owners

        Just as good genes do not guarantee health and well-being, a good design alone does not ensure a data center is well-built and will remain efficient and available over the course of its life span. For each phase of the data center’s life cycle, proper care and action must be taken to continuously meet the business needs of the facility. This paper describes the five phases of the data center life cycle, identifies key tasks and pitfalls, and offers practical advice to facility owners and management. Read White Paper #195
      • Read more about Schneider Electric solutions

        White Paper #135
        Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

        Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers. Read White Paper #135
    • Learn

      Data Center Efficiency Calculator

      Impact of alternative power and cooling approaches on energy costs. Efficiency Calculator

      Data Center Design Planning Calculator

      Impact of physical infrastructure technology and growth plan strategies on key design parameters. Design Planning Calculator

      Reference Design Selector

      Browse the Schneider Electric library of reference designs to select, compare and choose the optimal design that meets your data center needs. Reference Design Selector
    • Watch

      • The Data Center Transformed

        Want to be blown away? See how Schneider Electric's solutions will transform your data center.
      • Data Centers at Your Door: Prefabricated Modules from Schneider Electric

        Take a look at what's coming your way. Prefabricated IT and hydronics modules from Schneider Electric. While you prep your site, we build your data center and deliver it right to your facility.
      • DCIM, the Data Center Manager and the Software Defined Data Center

        The rise of DCIM and the software defined data center may mean the data center manager will manage IT equipment in the future as the IT focus shifts to abstracted or virtualized IT provision.
      • EcoStruxure™ for Data Centres

        Problem: new technologies are putting significant stress on our data centers. Solution: EcoStruxure by Schneider Electric. Schneider Electrics data center management software optimizes power utilization effectiveness (PUE) in data centers by expanding visibility & control from rack to row to room to building.